Breeze™

Breeze™ is a palm-size spectrometer for 400-1700nm equipped with an internal broadband light source, internal battery, the ability for Bluetooth connectivity and the LightSpec smartphone application.

Notify me on updates of this product 

Availability: Commercially Available

Jeff MacCubbin
Applications Specialist & Co-Founder
jmaccubbin@bayspec.com
+1 505 294 5654
155 Wyoming NE
Albuquerque, NM 87123
USA
+1 408-512-5928
1101 McKay Drive
San Jose, CA 95131
www.bayspec.com
Manufacturer
Bay Spec
Product Name
Breeze™
Detection Category
Chemical; Biological; Explosives;
Detection Principle
Molecular Spectroscopy;
Detection Method
Near Infrared;
Application
Emergency Response;Gas Analysis;
Equipment Type
Instrument
Product Synopsis
Breeze™ is a palm-size spectrometer for 400-1700nm equipped with an internal broadband light source, internal battery, the ability for Bluetooth connectivity and the LightSpec smartphone application.
Availability
Commercially Available
Technology Readiness Level (TRL)
9
Market Entry Date
May 2018
User Feedback Sources
Indifferent/No user feedback
Supporting Documentation
Docs: BaySpec-Breeze.pdf;
Dimensions
1.1 x 2.0 x 3.7 in (2.9 x 5.2 x 9.3 cm)
Weight
<1 lb.; 0.29 lbs (0.133 kg)
Power Requirements
Lithium Battery; Li-ion battery (2 hours continuous use), rechargable
Transportability
Pocket Size
Ruggedness
Extreme Temperatures/Humidity
Operating Conditions
-20 to 45°C (-4 to 113°F)
Consumables
None
Calibration Schedule
None; fixed calibration
Suggested Routine Maintenance
Software updates
Data Analysis Support Equipment
Smartphone, laptop
Communications Interface
Bluetooth, USB 2.0
Shelf Life
>5 years
Unit Cost
$7,900.00
Tested For Chemical Agents
Yes, including BZ
Tested For ITF-25 TIC/TIMs
Yes
Tested For Explosives
Yes
Tested For Narcotics
Fentanyl and analogs, heroin, ketamine, lorazepam
Other Chemical Targets
Yes
Number of Library Entries
30
Adaptability
Yes; user can add new targets to detector with support
Sample Introduction
Liquid;Solid;Vapor/Gas;
Sensitivity/Detection Limits
ppm; ppth
Start Up Time (From Cold Start To Sample Ready)
1 minute
Response Time (Sample Application To Output)
Continuous (<30 seconds); 1 second
Total Run Time
1 to 2 minutes
Alarm Capability
Visual
Software Control
Laptop, remote
Other Operational Parameters
Wavelength Range: 400 to 1000 nm or 900 to 1700 nm; Broadband light source
Training Required
<1 day training
Training Available
On-site, 1 day
Manuals Available
Yes
IATA Shipping Restrictions
Yes; Lithium ion battery