B220 Series
The B220 series devices are desktop real-time explosives and drug trace detectors. The B220-HT model is for high throughput. The devices feature a patented Dynamic Cleaning, which optimizes the unit for sampling on hands for high traffic environments. Dynamic Cleaning ensures optimal system performance and is resistant to contamination. The devices are Photonic (non-radioactive ionization).
Availability: Commercially Available
Manufacturer |
| Leidos |
Product Name |
| B220 Series |
Detection Category |
| Chemical; Explosives |
Detection Principle |
| Spectrometry; |
Detection Method |
| Ion Mobility Spectrometry; |
Application |
| Emergency Response;Trace Analysis; |
Product Model Number |
| B220, B220-HT, QS B220-HT (Formerly by Implant Sciences) |
Equipment Type |
| Instrument |
Product Synopsis |
| The B220 series devices are desktop real-time explosives and drug trace detectors. The B220-HT model is for high throughput. The devices feature a patented Dynamic Cleaning, which optimizes the unit for sampling on hands for high traffic environments. Dynamic Cleaning ensures optimal system performance and is resistant to contamination. The devices are Photonic (non-radioactive ionization). |
Availability |
| Commercially Available |
Technology Readiness Level (TRL) |
| 9 |
User Feedback Sources |
| Indifferent/No user feedback |
Dimensions |
| Without printer: 16.73 x 15.90 x 14.53 in (42.5 x 40.4 x 36.9 cm)
With printer: 16.73 x 15.90 x 15.71 in (42.5 x 40.4 x 39.9 cm) |
Weight |
| <50 lbs.; Without printer: 32.19 lbs (14.60 kg)
With printer: 34.61 lbs(15.70 kg) |
Power Requirements |
| AC/DC Line Power; 100-240 V AC, 47-63Hz |
Transportability |
| Benchtop/Fixed; Small Footprint |
Operating Conditions |
| -15 to 55°C (5 to 131°F), < 95% RH, |
Consumables |
| <$1,000/year; Molecular sieve drying agent, sample traps |
Calibration Schedule |
| Fully automated internal calibration |
Suggested Routine Maintenance |
| Cleaning and desiccant replacement as required |
Available Accessories |
| Optional built-in printer |
Data Analysis Support Equipment |
| Printer, 12.5 in high-resolution color touch screen |
Communications Interface |
| USB 2.0, RJ-45, VGA port |
Expected Operational Life |
| 10 years |
Shelf Life |
| >5 years |
Unit Cost |
| $25,900.00 |
Tested For ITF-25 TIC/TIMs |
| Yes |
Tested For Explosives |
| Wide variety of explosives (military, commercial, HME's) Including Ammonium Nitrate, ANFO, Blackpowder, C-4, Detasheet, Detonating cords, Dinitroluene, DMNB, Dynamite,EGDN, HMTD, HMX, Nitroglycerin, Peroxides, PETN, RDX, Somkeless powder, Teryl, Triacetone Triperoxide, Trinitrotoluene, Urea Nitrate, Semtex |
Tested For Narcotics |
| Wide variety including Cocaine, Heroin, THC, Methamphetamine, L-amphetamine, MDMA, MDA, Morphine, Ketamine. |
Adaptability |
| Yes; user can add new targets in the field |
Sample Introduction |
| Liquid;Solid;Vapor/Gas; |
Sensitivity/Detection Limits |
| ng; 1 to 50 ng (narcotics) |
False Positive Rates |
| Low |
False Negative Rates |
| Low |
Start Up Time (From Cold Start To Sample Ready) |
| <30 minutes |
Response Time (Sample Application To Output) |
| Continuous (<30 seconds); <10 seconds |
Total Run Time |
| < 30 minutes |
Alarm Capability |
| Audible and visual |
Software Control |
| On-board |
Other Operational Parameters |
| Photonic (non-radioactive ionization).% |
Training Required |
| <1 day training |
Manuals Available |
| Yes |
Warranties |
| Yes |