Chem-200

The CHEM-200 is handheld Raman analyzer with a 785 nm laser with continuous and preset adjustable laser focus. It eliminates the most common error whereby the laser is focused on the sample holder rather than the sample material itself. The CHEM-200 offers two vial sizes – the standard 15 ml and smaller 8 ml vials – in one vial holder.

Notify me on updates of this product 

Availability: Commercially Available

Don Sackett
sales@sciaps.com
+1 339 927 9455
2 Constitution Way
Woburn MA 01801
USA
SciAps Manufacturing & Service
5452 Aerospace Drive
Laramie, WY 82070
www.sciaps.com
Manufacturer
SciAps, Inc.
Product Name
Chem-200
Detection Category
Chemical; Explosives
Detection Principle
Molecular Spectroscopy;
Detection Method
Raman Spectroscopy;
Application
Emergency Response;Screening;Bulk Analysis;Trace Analysis;
Equipment Type
Instrument
Product Synopsis
The CHEM-200 is handheld Raman analyzer with a 785 nm laser with continuous and preset adjustable laser focus. It eliminates the most common error whereby the laser is focused on the sample holder rather than the sample material itself. The CHEM-200 offers two vial sizes – the standard 15 ml and smaller 8 ml vials – in one vial holder.
Availability
Commercially Available
Technology Readiness Level (TRL)
9
Market Entry Date
January 2020
User Feedback Sources
Indifferent/No user feedback
Weight
<30 lbs.; < 10 lbs. (4.5 kg)
Power Requirements
Lithium Battery
Transportability
Handheld
Ruggedness
Waterproof/Resistant; Dust; Vibration/Shock; IP67, Mil Spec 810G
Consumables
None
Solvents/Reagents
None
Calibration Schedule
Automatic self-test
Suggested Routine Maintenance
Minimal
Data Analysis Support Equipment
5.5 in color touch screen
Communications Interface
Wi-Fi, Bluetooth, GPS on-board (can be hardware disabled)
Expected Operational Life
Indefinite
Maintenance Cost
Minimal
Tested For Chemical Agents
Yes
Tested For ITF-25 TIC/TIMs
Yes
Tested For Explosives
Yes
Tested For Narcotics
Yes
Other Chemical Targets
Yes
Adaptability
Yes; user can add new targets in the field
Sample Introduction
Liquid;Solid;
Sensitivity/Detection Limits
Bulk; mg; g; %
Known Interferents/Inhibitors
Fluorescence
Response Time (Sample Application To Output)
Continuous (<30 seconds); 10 seconds
Software Control
On-board
Other Operational Parameters
Macro-camera for photo-documentation of samples tested, or to read 2D bar codes for sample logging and tracking
Training Required
<1 day training
Training Available
Yes
Manuals Available
Yes
IATA Shipping Restrictions
Yes; Lithium ion batteries
Please enter contact info.
Email Address: 
Company: 
Name: 
Title: