Explosives and Narcotics Detector and Scanners Technologies
The instrument uses vacuum ultraviolet (VUV) lamp soft ionization technology, for safe non- radioactive use for detection of explosives and narcotics.
Availability: DISCONTINUED
Manufacturer |
| Aventura Technologies, Inc. |
Product Name |
| Explosives and Narcotics Detector and Scanners Technologies |
Detection Category |
| Chemical; Explosives |
Detection Principle |
| Spectrometry; |
Detection Method |
| Ion Mobility Spectrometry; |
Application |
| Emergency Response;Screening; |
Equipment Type |
| Instrument |
Product Synopsis |
| The instrument uses vacuum ultraviolet (VUV) lamp soft ionization technology, for safe non- radioactive use for detection of explosives and narcotics. |
Availability |
| DISCONTINUED |
Technology Readiness Level (TRL) |
| 9 |
User Feedback Sources |
| Indifferent/No user feedback |
Dimensions |
| 15.75 x 15 x 9.85 in (40 x 38.2 x 25 cm) |
Weight |
| <50 lbs.; 33 lbs (15kg) |
Power Requirements |
| AC/DC Line Power; 110 VAC / 220 VAC |
Transportability |
| Person-Portable |
Operating Conditions |
| -10 to 50°C (14 to 122°F), 0 to 95% RH non-condensing |
Consumables |
| <$1,000/year; Sampling wipes |
Solvents/Reagents |
| None |
Suggested Routine Maintenance |
| Automatic cleaning |
Available Accessories |
| Reusable dipstick |
Data Analysis Support Equipment |
| On-board printer, 10? TFT color touch screen |
Communications Interface |
| USB |
Expected Operational Life |
| Indefinite |
Shelf Life |
| >5 years |
Maintenance Cost |
| None |
Tested For ITF-25 TIC/TIMs |
| No |
Tested For Explosives |
| Nitroglycerine nitrification, ammonium nitrate black powder |
Tested For Narcotics |
| Cocaine, hydrochloric acid heroin, tetrahydrocar- bonanabinol, methylaniline (methamphetamine), ketamine hydrochloride, ecstasy, pethidine |
Other Chemical Targets |
| No |
Tested For Biological Agents |
| No |
Adaptability |
| Yes; user can add new targets in the field and create custom searchable libraries |
Sample Introduction |
| Solid; |
Sensitivity/Detection Limits |
| ng |
False Positive Rates |
| < 1 % |
False Negative Rates |
| < 1 % |
Start Up Time (From Cold Start To Sample Ready) |
| < 15 minutes |
Response Time (Sample Application To Output) |
| Continuous (<30 seconds); < 6 seconds |
Total Run Time |
| < 16 minutes |
Alarm Capability |
| Audible and visual |
Software Control |
| On-board |
Other Operational Parameters |
| Text print or picture |
Training Required |
| <1 day training |
Training Available |
| No |
Manuals Available |
| Yes |
Reachback Service |
| No |
Warranties |
| 1 year |