Personal Radiation Monitors

The instrument will automatically alarm with an audible signal and blinking display when either the dose rate (0.01 mR/hr to 999 R/hr) or accumulated dose (0 to 1999 R) setpoints are exceeded. The dose is recorded until manually reset and is for use as reference only; it is not intended for legal dose recording. This small device can be worn on a belt, lanyard, or armband. Intrinsically safe models (IS) available.

Notify me on updates of this product 

Availability: Commercially Available

Jeff Anspaugh
jeff@degtech.com
+1 317 512 0010
PO BOX 810
Sweetwater, Texas 79556
USA
ludlum@ludlums.com
+1 800 622 0828
www.ludlums.com
Manufacturer
Ludlum Measurements, Inc.
Product Name
Personal Radiation Monitors
Detection Category
Radiological/Nuclear;
Detection Principle
Semiconductors;
Detection Method
Semiconductors;
Application
Personal Radiation Detectors;
Product Model Number
Model 25 series, 25-IS, 25-IS-1
Equipment Type
Instrument
Product Synopsis
The instrument will automatically alarm with an audible signal and blinking display when either the dose rate (0.01 mR/hr to 999 R/hr) or accumulated dose (0 to 1999 R) setpoints are exceeded. The dose is recorded until manually reset and is for use as reference only; it is not intended for legal dose recording. This small device can be worn on a belt, lanyard, or armband. Intrinsically safe models (IS) available.
Availability
Commercially Available
Technology Readiness Level (TRL)
9
User Feedback Sources
Indifferent/No user feedback
Supporting Documentation
Docs: Ludlum_M25 Series PRMonitors.pdf;
Dimensions
3.0 x 2.1 x 0.69 in (7.6 x 5.4 x 1.7 cm)
Weight
<1 lb.; 5.1 oz (144 g)
Power Requirements
Lithium Battery; Two lithium coin cell batteries (6,000 hours)
Noise Produced
95 dB at 0.3 m (1.0 ft.)
Transportability
Pocket Size
Ruggedness
Extreme Temperatures/Humidity
Operating Conditions
-40 to 65 °C (-40 to 150 °F)
Consumables
None
Solvents/Reagents
None
Calibration Schedule
None
Suggested Routine Maintenance
None
Available Accessories
Armband, nylon case
Data Analysis Support Equipment
None
Expected Operational Life
Indefinite
Shelf Life
>5 years
Maintenance Cost
None
Radiological Targets
Gamma
Sample Introduction
Radioactive Particle
Sensitivity/Detection Limits
mR; 0.01 mR/hr to 999 R/hr
Start Up Time (From Cold Start To Sample Ready)
< 1 minute
Response Time (Sample Application To Output)
Continuous (<30 seconds)
Total Run Time
Continuous
Alarm Capability
Audible, visual
Software Control
On-board
Other Operational Parameters
None
Training Required
<1 day training
Training Available
No
Manuals Available
Yes
Please enter contact info.
Email Address: 
Company: 
Name: 
Title: