X-am® 8000

Dräger X-am® 8000 measures up to seven toxic as well as flammable gases, vapors and oxygen all at once — either in pump or diffusion mode. The internal pump can be connected with hoses of up to 45 meters in length.

Notify me on updates of this product 

Availability: Commercially Available

+1 800 437 2437
7256 South Sam Houston Parkway, Suite 100
Houston, TX 77085
USA
+49 451 8842
Moislinger Allee 53-77
23580 Lübeck
Germany
www.draeger.com
Manufacturer
Dräger Safety, Inc.
Product Name
X-am® 8000
Detection Category
Chemical
Detection Principle
Sensors;
Detection Method
Photoionization Detection;
Application
Gas Analysis;
Equipment Type
Instrument
Product Synopsis
Dräger X-am® 8000 measures up to seven toxic as well as flammable gases, vapors and oxygen all at once — either in pump or diffusion mode. The internal pump can be connected with hoses of up to 45 meters in length.
Availability
Commercially Available
Technology Readiness Level (TRL)
9
User Feedback Sources
Indifferent/No user feedback
Dimensions
7.0 x 3.0 x 1.7 in (17.9 x 7.7 x 4.2 cm)
Weight
<5 lbs.; 17.5 oz (495 g)
Power Requirements
Lithium Battery; 20 hours
Noise Produced
100 dB
Transportability
Handheld
Ruggedness
Extreme Temperatures/Humidity; Waterproof/Resistant; Dust; IP67, rubber boot
Operating Conditions
-20 to 50°C (-4 to 122°F), < 90% RH non-condensing
Consumables
<$1,000/year; Sensors
Solvents/Reagents
Calibration gases
Calibration Schedule
Bump test and calibration are carried out using the Dräger X-dock® calibrating station.
Suggested Routine Maintenance
None
Available Accessories
Shoulder strap, pump adapter, pre-tube holder
Data Analysis Support Equipment
X-dock Manager PC software
Communications Interface
USB Dira Dongle / IR interface
Expected Operational Life
Indefinite
Shelf Life
>5 years
Maintenance Cost
None
Other Chemical Targets
Oxygen, carbon dioxide, hydrogen sulfide, nitrogen dioxide, sulfur dioxide
Adaptability
No
Sample Introduction
Vapor/Gas;
Sensitivity/Detection Limits
ppm
Start Up Time (From Cold Start To Sample Ready)
< 60 seconds
Response Time (Sample Application To Output)
Continuous (<30 seconds)
Total Run Time
Continuous monitor
Alarm Capability
Audible, visual, and vibrational
Software Control
On-board
Other Operational Parameters
12 MB storage
Training Required
<1 day training
Training Available
Yes
Manuals Available
Yes
Warranties
3 year
IATA Shipping Restrictions
Yes; Lithium-ion battery
Please enter contact info.
Email Address: 
Company: 
Name: 
Title: