RadPavise-H
RadPavise-H | Personal Radiation Detector uses a YSO scintillation detector combined with a state-of-the-art silicon photomultiplier (YSO+SiPM) and multi-voltage threshold (MVT) algorithm to detect a wide range of radiation doses.
Proportional, real-time detection and measurement provide meaningful readouts that focus on real-world applications. The fast response and wide dose rate range maximize the safety of your team. Intuitive navigation allows users to adjust settings in the field.
The unique, high-contrast OLED display provides a clear indication of the wearer’s equivalent dose rate, accumulated dose, and count rate. The search interface can also be used as a survey meter to locate the source of radiation.
RadPavise-H | Personal Radiation Detector is designed to meet the needs of emergency responders and radiation protection personnel across the United States.
Availability: Commercially Available
Manufacturer |
| X-Z Lab Inc. |
Product Name |
| RadPavise-H |
Detection Category |
| Radiological/Nuclear; |
Detection Principle |
| Scintillation Detectors; |
Detection Method |
| Scintillation Detectors; |
Application |
| Personal Radiation Detectors; |
Equipment Type |
| Instrument |
Product Synopsis |
| RadPavise-H | Personal Radiation Detector uses a YSO scintillation detector combined with a state-of-the-art silicon photomultiplier (YSO+SiPM) and multi-voltage threshold (MVT) algorithm to detect a wide range of radiation doses.
Proportional, real-time detection and measurement provide meaningful readouts that focus on real-world applications. The fast response and wide dose rate range maximize the safety of your team. Intuitive navigation allows users to adjust settings in the field.
The unique, high-contrast OLED display provides a clear indication of the wearer’s equivalent dose rate, accumulated dose, and count rate. The search interface can also be used as a survey meter to locate the source of radiation.
RadPavise-H | Personal Radiation Detector is designed to meet the needs of emergency responders and radiation protection personnel across the United States. |
Availability |
| Commercially Available |
Technology Readiness Level (TRL) |
| 9 |
User Feedback Sources |
| Indifferent/No user feedback |
Dimensions |
| 4.72 x 2.95x 1.26 in (12 x 7.5 x 3.2 cm) |
Weight |
| <1 lb.; 0.36 lb (165 g) |
Power Requirements |
| Alkaline Battery (AAA*4); Rechargeable Lithium-Ion Battery (500 hours) |
Noise Produced |
| 80 dB |
Transportability |
| Pocket Size |
Ruggedness |
| Waterproof/Resistant; Dust; IP65 |
Operating Conditions |
| 0 to 55°C (32 to 131°F), <95% RH non-condensing |
Consumables |
| Batteries |
Calibration Schedule |
| Auto-calibration |
Available Accessories |
| External probe for Alpha and Beta |
Data Analysis Support Equipment |
| PC software |
Communications Interface |
| MicroUSB |
Expected Operational Life |
| Indefinite |
Shelf Life |
| >5 years |
Radiological Targets |
| Alpha, Beta, Gamma, X-Ray |
Sample Introduction |
| Radioactive Particle |
Sensitivity/Detection Limits |
| 980 cps/mrem/h (98 cps/µSv/h) (? Cs-137) |
Response Time (Sample Application To Output) |
| Continuous (<30 seconds); < 2 seconds |
Total Run Time |
| Continuous monitor |
Alarm Capability |
| Audible, visual, vibrational |
Software Control |
| On-board, PC |
Other Operational Parameters |
| Detector: silicon photomultiplier and YSO scintillator, |
Training Required |
| <1 hour training |
Manuals Available |
| Yes |
Warranties |
| Yes |