ETD-100™

GreyScan offers explosive trace detection for inorganic explosives. The GreyScan system utilizes Capillary Zone Electrophoresis (CZE) technology for the separation and analysis of samples. The underlying principal of this separation method is similar to Ion Mobility Spectrometry, except the separation occurs in an aqueous phase rather than in the gaseous phase. The CZE detection method does not require the use of a radioactive source, removing the need for time-consuming radiation testing or transportation licenses. This makes it an environmentally friendly and safe solution for trace explosive detection

Notify me on updates of this product 

Availability: Commercially Available

+613 9112 0333
9/435 Williamstown Road
Port Melbourne, Victoria 3207
Australia
www.greyscandetection.com
Manufacturer
GreyScan Pty Ltd
Product Name
ETD-100™
Detection Category
Chemical; Explosives
Detection Principle
Spectrometry;
Detection Method
Capillary Zone Electrophoresis;
Application
Emergency Response;
Equipment Type
Instrument
Product Synopsis
GreyScan offers explosive trace detection for inorganic explosives. The GreyScan system utilizes Capillary Zone Electrophoresis (CZE) technology for the separation and analysis of samples. The underlying principal of this separation method is similar to Ion Mobility Spectrometry, except the separation occurs in an aqueous phase rather than in the gaseous phase. The CZE detection method does not require the use of a radioactive source, removing the need for time-consuming radiation testing or transportation licenses. This makes it an environmentally friendly and safe solution for trace explosive detection
Availability
Commercially Available
Technology Readiness Level (TRL)
9
User Feedback Sources
Indifferent/No user feedback
Dimensions
19.2 x 15.2 x 9.0 in (48.8 x 38.6 x 22.9 cm)
Weight
<30 lbs.; 28.9 lbs. (13.1 kg)
Power Requirements
AC/DC Line Power; Lithium Battery; 100-240 V AC, 50-60 Hz, battery (1 to 8 hours)
Transportability
Person-Portable
Operating Conditions
5 to 55°C (40 to 130°F), 5 to 95% RH non-condensing
Consumables
>$1,000/year; Sample traps, reagents, filters, verification samples
Solvents/Reagents
None
Calibration Schedule
Automatic internal self-calibration
Data Analysis Support Equipment
PC
Communications Interface
Serial port, Ethernet, Wi-Fi, USB 2.0
Expected Operational Life
5 to 10 years
Shelf Life
>5 years
Unit Cost
$45,000.00
Tested For Explosives
Chlorates, perchlorates, nitrates
Sample Introduction
Vapor/Gas;
Sensitivity/Detection Limits
ng; 50 to 100 ng
Start Up Time (From Cold Start To Sample Ready)
10 minutes
Response Time (Sample Application To Output)
<1 minute; 40 seconds
Software Control
On-board, Remote
Training Required
<1 day training
Training Available
Yes
Manuals Available
Yes
Reachback Service
No
Warranties
Yes