ETD-100™
GreyScan offers explosive trace detection for inorganic explosives. The GreyScan system utilizes Capillary Zone Electrophoresis (CZE) technology for the separation and analysis of samples. The underlying principal of this separation method is similar to Ion Mobility Spectrometry, except the separation occurs in an aqueous phase rather than in the gaseous phase. The CZE detection method does not require the use of a radioactive source, removing the need for time-consuming radiation testing or transportation licenses. This makes it an environmentally friendly and safe solution for trace explosive detection
Availability: Commercially Available
Manufacturer |
| GreyScan Pty Ltd |
Product Name |
| ETD-100™ |
Detection Category |
| Chemical; Explosives |
Detection Principle |
| Spectrometry; |
Detection Method |
| Capillary Zone Electrophoresis; |
Application |
| Emergency Response; |
Equipment Type |
| Instrument |
Product Synopsis |
| GreyScan offers explosive trace detection for inorganic explosives. The GreyScan system utilizes Capillary Zone Electrophoresis (CZE) technology for the separation and analysis of samples. The underlying principal of this separation method is similar to Ion Mobility Spectrometry, except the separation occurs in an aqueous phase rather than in the gaseous phase. The CZE detection method does not require the use of a radioactive source, removing the need for time-consuming radiation testing or transportation licenses. This makes it an environmentally friendly and safe solution for trace explosive detection |
Availability |
| Commercially Available |
Technology Readiness Level (TRL) |
| 9 |
User Feedback Sources |
| Indifferent/No user feedback |
Dimensions |
| 19.2 x 15.2 x 9.0 in (48.8 x 38.6 x 22.9 cm) |
Weight |
| <30 lbs.; 28.9 lbs. (13.1 kg) |
Power Requirements |
| AC/DC Line Power; Lithium Battery; 100-240 V AC, 50-60 Hz, battery (1 to 8 hours) |
Transportability |
| Person-Portable |
Operating Conditions |
| 5 to 55°C (40 to 130°F), 5 to 95% RH non-condensing |
Consumables |
| >$1,000/year; Sample traps, reagents, filters, verification samples |
Solvents/Reagents |
| None |
Calibration Schedule |
| Automatic internal self-calibration |
Data Analysis Support Equipment |
| PC |
Communications Interface |
| Serial port, Ethernet, Wi-Fi, USB 2.0 |
Expected Operational Life |
| 5 to 10 years |
Shelf Life |
| >5 years |
Unit Cost |
| $45,000.00 |
Tested For Explosives |
| Chlorates, perchlorates, nitrates |
Sample Introduction |
| Vapor/Gas; |
Sensitivity/Detection Limits |
| ng; 50 to 100 ng |
Start Up Time (From Cold Start To Sample Ready) |
| 10 minutes |
Response Time (Sample Application To Output) |
| <1 minute; 40 seconds |
Software Control |
| On-board, Remote |
Training Required |
| <1 day training |
Training Available |
| Yes |
Manuals Available |
| Yes |
Reachback Service |
| No |
Warranties |
| Yes |