D7 AFC-380 5 Gal High Expansion Foam
AFC-380 must be deployed into a containment structure (supplied separately) using a foam educator (supplied separately). AFC-380 foam is used to reduce blast overpressures and for particle containment. AFC-380 contains surfactants, mild solvents, and polymer thickeners and can be deployed as a 3% or 6% concentrate.
D7™ is safe for application on glass, laminated surfaces, metal, stainless steel, glazed porcelain, glazed ceramic, sealed granite, sealed marble, plastic, (such as polycarbonate, polyvinylchloride, polystyrene or polypropylene), sealed limestone, sealed slate, sealed stone, sealed terra cotta, sealed terrazzo, chrome, Plexiglas®, vanity tops. D7™ will not damage or stain most fabrics.
Availability: Commercially Available
+1 480 339 2857
8541 East Anderson Drive, Suite 10
Scottsdale, AZ 85255
USA
|
|
www.decon7.com
Manufacturer |
| Decon7 Systems |
Product Name |
| D7 AFC-380 5 Gal High Expansion Foam |
Detection Category |
| Chemical; Biological |
Detection Method |
| PPE/Decon |
Application |
| Decontamination; |
Equipment Type |
| Decontamination |
Product Synopsis |
| AFC-380 must be deployed into a containment structure (supplied separately) using a foam educator (supplied separately). AFC-380 foam is used to reduce blast overpressures and for particle containment. AFC-380 contains surfactants, mild solvents, and polymer thickeners and can be deployed as a 3% or 6% concentrate.
D7™ is safe for application on glass, laminated surfaces, metal, stainless steel, glazed porcelain, glazed ceramic, sealed granite, sealed marble, plastic, (such as polycarbonate, polyvinylchloride, polystyrene or polypropylene), sealed limestone, sealed slate, sealed stone, sealed terra cotta, sealed terrazzo, chrome, Plexiglas®, vanity tops. D7™ will not damage or stain most fabrics. |
Availability |
| Commercially Available |
Technology Readiness Level (TRL) |
| 9 |
User Feedback Sources |
| Indifferent/No user feedback |
Weight |
| <30 lbs. |
Power Requirements |
| None |
Transportability |
| Handheld |
Operating Conditions |
| 0 to 49°C (33 to 120°F); D7™ freezing point is 0°C (32°F); boiling point is 93°C (200°F). Degradation begins above 49°C (120°F) |
Active Mechanism |
| Part 1: A surfactant (Quaternary Ammonium Compound)
Part 2: An oxidizer (Hydrogen Peroxide)
Part 3: An optional accelerator (Diacetin) |
Water/Oil Based |
| Water |
Effective Against |
| Staphylococcus aureus (ATCC 6538),
Escherichia coli 0157:H7 (ATCC 35150) Salmonella enterica (ATCC 10708),
Pseudomonas aeruginosa (ATCC 15442), Staphylococcus aureus MRSA
(Methicillin resistant) (ATCC 33592) FUNGICIDAL AGAINST: Aspergillus
niger (ATCC 16404), Penicillium igitatum (ATCC 90595). It has also been used to clean methamphetamine labs and crime scenes. Recent testing also
indicates the potential to decontaminate Fentanyl. |
Form |
| Foam |
Used with Older/Newer Applicators |
| No |
Live Agent Tested |
| Yes |
NIOSH Approved |
| No |
Preparation Time |
| <15 minutes |
Sensitive or Electronic Use |
| No |
Size of Application |
| Large |
Standards Met |
| pH level of 9.6, D7™ meets NFPA 1851 requirements and has been tested per NFPA 1971 standards. |
Tested By |
| Multiple organizations |
Other Operational Parameters |
| D7™ is a skin and mucus membrane irritant. Do not get in eyes, on skin, or on clothing. D7™ is harmful if swallowed. The vapors may cause respiratory irritation. When contamination is discovered in a confined area, the use of a mask or pesticide respirator is recommended. If ingested, contact a poison control center |
Training Required |
| <1 hour training |
Training Available |
| Yes |
Manuals Available |
| Yes |