MMS-1000

1st Detect’s MMS-1000 ion trap mass spectrometer is designed for an array of measurements where size, trans-portability or cost, are important. This instrument adapts to a wide range of applications using multiple inlet configurations and customizable software. The Miniature Mass Spectrometer (MMS-1000) can be coupled to a variety of sample collection, pre-concentration, or separation systems to suit the needs of a particular application.

Notify me on updates of this product 

Availability: DISCONTINUED

sales@1stdetect.com
+1 512 485 9530
555 Forge River Road, Suite 100
Webster, TX 77598
USA
www.1stdetect.com
Manufacturer
1st Detect
Product Name
MMS-1000
Detection Category
Chemical; Explosives
Detection Principle
Spectrometry;
Detection Method
Ion Trap Mass Spectrometry;
Application
Emergency Response;Screening;Gas Analysis;
Product Model Number
MMS-1000
Equipment Type
Instrument
Product Synopsis
1st Detect’s MMS-1000 ion trap mass spectrometer is designed for an array of measurements where size, trans-portability or cost, are important. This instrument adapts to a wide range of applications using multiple inlet configurations and customizable software. The Miniature Mass Spectrometer (MMS-1000) can be coupled to a variety of sample collection, pre-concentration, or separation systems to suit the needs of a particular application.
Availability
DISCONTINUED
Technology Readiness Level (TRL)
9
Market Entry Date
2016
User Feedback Sources
Indifferent/No user feedback
Dimensions
7.5 x 13 x 9 in (19 x 33 x 23 cm)
Weight
<30 Lbs.; < 17 lbs (8 kg)
Power Requirements
AC/DC Line power; Supplied Universal 110/220 VAC supply
Transportability
Person-Portable
Ruggedness
None
Consumables
<$1,000/year
Data Analysis Support Equipment
PC, software
Communications Interface
Ethernet; bluetooth
Expected Operational Life
Indefinite
Shelf Life
>5 years
Tested For Chemical Agents
Yes
Tested For ITF-25 TIC/TIMs
Yes
Tested For Explosives
Yes
Tested For Narcotics
Yes
Adaptability
Yes; manufacturer can add new targets to detector
Sample Introduction
Vapor/Gas;
Sensitivity/Detection Limits
ppb; ppt
Start Up Time (From Cold Start To Sample Ready)
< 20 minutes
Response Time (Sample Application To Output)
Continuous (<30 seconds); sampling has real-time analysis or 30 sec response time (based upon 5 sec sampling and 25 sec analysis)
Software Control
On-board, PC
Other Operational Parameters
MS/MS CAPABLE: No collisional gas or buffer gas required. Settable mass ranges are: 15 to 45 amu, 45 to 400 amu, 100 to 500 amu.
Training Required
>1 week training
Training Available
Yes
Manuals Available
Yes
IATA Shipping Restrictions
No