MMS-1000
1st Detect’s MMS-1000 ion trap mass spectrometer is designed for an array of measurements where size, trans-portability or cost, are important. This instrument adapts to a wide range of applications using multiple inlet configurations and customizable software. The Miniature Mass Spectrometer (MMS-1000) can be coupled to a variety of sample collection, pre-concentration, or separation systems to suit the needs of a particular application.
Availability: DISCONTINUED
Manufacturer |
| 1st Detect |
Product Name |
| MMS-1000 |
Detection Category |
| Chemical; Explosives |
Detection Principle |
| Spectrometry; |
Detection Method |
| Ion Trap Mass Spectrometry; |
Application |
| Emergency Response;Screening;Gas Analysis; |
Product Model Number |
| MMS-1000 |
Equipment Type |
| Instrument |
Product Synopsis |
| 1st Detect’s MMS-1000 ion trap mass spectrometer is designed for an array of measurements where size, trans-portability or cost, are important. This instrument adapts to a wide range of applications using multiple inlet configurations and customizable software. The Miniature Mass Spectrometer (MMS-1000) can be coupled to a variety of sample collection, pre-concentration, or separation systems to suit the needs of a particular application. |
Availability |
| DISCONTINUED |
Technology Readiness Level (TRL) |
| 9 |
Market Entry Date |
| 2016 |
User Feedback Sources |
| Indifferent/No user feedback |
Dimensions |
| 7.5 x 13 x 9 in (19 x 33 x 23 cm) |
Weight |
| <30 Lbs.; < 17 lbs (8 kg) |
Power Requirements |
| AC/DC Line power; Supplied Universal 110/220 VAC supply |
Transportability |
| Person-Portable |
Ruggedness |
| None |
Consumables |
| <$1,000/year |
Data Analysis Support Equipment |
| PC, software |
Communications Interface |
| Ethernet; bluetooth |
Expected Operational Life |
| Indefinite |
Shelf Life |
| >5 years |
Tested For Chemical Agents |
| Yes |
Tested For ITF-25 TIC/TIMs |
| Yes |
Tested For Explosives |
| Yes |
Tested For Narcotics |
| Yes |
Adaptability |
| Yes; manufacturer can add new targets to detector |
Sample Introduction |
| Vapor/Gas; |
Sensitivity/Detection Limits |
| ppb; ppt |
Start Up Time (From Cold Start To Sample Ready) |
| < 20 minutes |
Response Time (Sample Application To Output) |
| Continuous (<30 seconds); sampling has real-time analysis or 30 sec response time (based upon 5 sec sampling and 25 sec analysis) |
Software Control |
| On-board, PC |
Other Operational Parameters |
| MS/MS CAPABLE: No collisional gas or buffer gas required. Settable mass ranges are: 15 to 45 amu, 45 to 400 amu, 100 to 500 amu. |
Training Required |
| >1 week training |
Training Available |
| Yes |
Manuals Available |
| Yes |
IATA Shipping Restrictions |
| No |