TRACER 1000 MS-ETDTM

1ST Detect’s TRACER 1000 MS-ETDTM is an Explosives Trace Detection solution representing a linear ion trap mass spectrometer with a swab-based thermal desorption sample inlet system. The system is designed to be capable of detecting a wide range of compounds which are semi-volatile and/or nonvolatile, including explosives, drugs of abuse, and chemical warfare agents. The instrument uses chemical ionization. MS/MS capabilities allow verification of any positive results.

Notify me on updates of this product 

Availability: Commercially Available

Nicholas Roach
nroach@astrotechcorp.com
+1 512 485 9539
555 Forge River Road, Suite 100
Webster, TX 77598
USA
www.1stdetect.com
Manufacturer
1st Detect
Product Name
TRACER 1000 MS-ETDTM
Detection Category
Chemical; Explosives
Detection Principle
Spectrometry;
Detection Method
Ion Trap Mass Spectrometry;
Application
Trace Analysis;Emergency Response;Forensics;
Equipment Type
Instrument
Product Synopsis
1ST Detect’s TRACER 1000 MS-ETDTM is an Explosives Trace Detection solution representing a linear ion trap mass spectrometer with a swab-based thermal desorption sample inlet system. The system is designed to be capable of detecting a wide range of compounds which are semi-volatile and/or nonvolatile, including explosives, drugs of abuse, and chemical warfare agents. The instrument uses chemical ionization. MS/MS capabilities allow verification of any positive results.
Availability
Commercially Available
Technology Readiness Level (TRL)
9
Market Entry Date
January 2018
User Feedback Sources
Indifferent/No user feedback
Dimensions
14.3 x 18.1 x 21 in (36 x 45 x 53 cm)
Weight
>50 Lbs.; 54 lbs (24 kg)
Power Requirements
AC/DC Line Power; 110 VAC / 230 VAC, 50 Hz / 60 Hz
Transportability
Benchtop/Fixed; Small Footprint
Ruggedness
None
Operating Conditions
0 to 40°C (32 to 104°F); < 95% RH, non-condensing
Consumables
<$1,000/year; TD Swabs, Air filters, calibrant tube
Suggested Routine Maintenance
Change out calibrant tube, air filter, ionizer detector annually
Available Accessories
Printer
Data Analysis Support Equipment
PC, software
Communications Interface
USB 2.0, ethernet
Expected Operational Life
>5 years
Shelf Life
>5 years
Unit Cost
$50,000.00
Maintenance Cost
< $100
Tested For Chemical Agents
Yes
Tested For ITF-25 TIC/TIMs
Yes
Tested For Explosives
Military, commercial-grade and home-made explosives (HMEs) such as TNT, RDX, Picric acid, R-salt, smokeless powders, PETN, NG, AN, UN, HMTD, TATP, EGDN and others; as well as peroxides and formulated threats
Tested For Narcotics
A broad range of narcotics, pharmaceutical drugs and controlled substances including fentanyl, fentanyl analogs, amphetamines, cocaine, heroin, and others
Other Chemical Targets
Yes
Other Biological Targets
Any solid organic material
Number of Library Entries
Unlimited
Adaptability
Yes; manufacturer can add new targets to detector
Sample Introduction
Vapor/Gas;Solid;Liquid;
Sensitivity/Detection Limits
pg; µg
Known Interferents/Inhibitors
Able to Identify targets in mixtures as long as the components of the mixture are in the library.
False Positive Rates
1.8%
Start Up Time (From Cold Start To Sample Ready)
20 minutes
Response Time (Sample Application To Output)
Continuous (<30 seconds); 10 seconds (library dependent)
Total Run Time
20 minutes
Alarm Capability
Audible and Visual
Software Control
On-board
Other Operational Parameters
Mass Range: 45 to 520 amu Resolution: 0.6 amu FWHM at 131 amu, 0.85 amu FWHM at 502 amu
Training Required
<1 week training
Training Available
Yes, 1 day
Manuals Available
Yes
Warranties
1 year
ITAR/EAR Export Regulations
No
IATA Shipping Restrictions
No
Please enter contact info.
Email Address: 
Company: 
Name: 
Title: