APEX
APEX is a solid-state gamma spectrometer. Custom sizes and AI powered software are available. Energy resolution is < 2.5% at 662 keV for rapid radioisotope detection and identification in first responder, process monitoring, inspection, and related applications. Modular and expandable architecture supports system configurations from small to large area mission objectives.
Availability: Commercially Available
Manufacturer |
| Rock West Solutions |
Product Name |
| APEX |
Detection Category |
| Radiological/Nuclear |
Detection Principle |
| Semiconductors; |
Detection Method |
| Semiconductors; |
Application |
| Identifiers; |
Equipment Type |
| Instrument |
Product Synopsis |
| APEX is a solid-state gamma spectrometer. Custom sizes and AI powered software are available. Energy resolution is < 2.5% at 662 keV for rapid radioisotope detection and identification in first responder, process monitoring, inspection, and related applications. Modular and expandable architecture supports system configurations from small to large area mission objectives.
|
Availability |
| Commercially Available |
Technology Readiness Level (TRL) |
| 8 |
Market Entry Date |
| February 2021 |
User Feedback Sources |
| Indifferent/No user feedback |
Dimensions |
| 6 x 4.1 x 2.2 in. (15 x 10.5 x 5.5 cm) |
Weight |
| <1 Lb.; 0.79 Lbs. (0.36 kg) |
Power Requirements |
| USB |
Transportability |
| Handheld |
Ruggedness |
| Extreme Temperatures/Humidity; Dust; Vibration/Shock; Waterproof/Resistant |
Operating Conditions |
| -30 to 50°C (-22 to 122°F) |
Consumables |
| None |
Calibration Schedule |
| Annual and included with purchase |
Suggested Routine Maintenance |
| Minimal |
Available Accessories |
| Tablet computer, Cables |
Data Analysis Support Equipment |
| Windows 10, APEX software |
Communications Interface |
| USB C |
Expected Operational Life |
| 5 years |
Shelf Life |
| >5 years |
Unit Cost |
| $9,995.00 |
Maintenance Cost |
| Minimal |
Radiological Targets |
| Gamma |
Number of Library Entries |
| User configurable |
Adaptability |
| No; cannot detect or add new targets |
Sample Introduction |
| Radioactive Particle; |
Sensitivity/Detection Limits |
| %; 1.25% |
Known Interferents/Inhibitors |
| Shielding |
Start Up Time (From Cold Start To Sample Ready) |
| 10 seconds |
Response Time (Sample Application To Output) |
| Continuous (<30 seconds) |
Total Run Time |
| Continuous |
Alarm Capability |
| No, but software could be easily modify for a visual alarm. |
Software Control |
| PC |
Other Operational Parameters |
| Energy resolution of < 2.5% at 662 keV |
Training Required |
| <1 hour training |
Training Available |
| Included with Purchase |
Manuals Available |
| Yes |
Reachback Service |
| Included with Purchase |
ITAR/EAR Export Regulations |
| Yes |
IATA Shipping Restrictions |
| Yes |
Data File Type Format |
| CSV |