identiFINDER® S900
The identiFINDER® S900 is an autonomous sensor delivering real-time radiation detection and identification. It detects the presence or movement of radioactive material across borders, into buildings, at large public gatherings, and events. The S900 is available in a wide variety of form factors that can be tailored to application-specific environments and sensitivities. Deployment can begin with a standalone system and expand to a network of systems as needs change.
Availability: Commercially Available
Manufacturer |
| Teledyne FLIR Detection, Inc. |
Product Name |
| identiFINDER® S900 |
Detection Category |
| Radiological/Nuclear; |
Detection Principle |
| Scintillation Detectors; Geiger-Muller Detectors; |
Detection Method |
| Scintillation Detectors;Geiger-Muller Detectors; |
Application |
| Identifiers; Port Screening; Survey Meter; |
Product Model Number |
| 203.2-NG, 203.2-NGH, 403.3-NG, 403.3-NGH, 416.1-NG, 416.1-NGH |
Equipment Type |
| Instrument |
Product Synopsis |
| The identiFINDER® S900 is an autonomous sensor delivering real-time radiation detection and identification. It detects the presence or movement of radioactive material across borders, into buildings, at large public gatherings, and events. The S900 is available in a wide variety of form factors that can be tailored to application-specific environments and sensitivities. Deployment can begin with a standalone system and expand to a network of systems as needs change. |
Availability |
| Commercially Available |
Technology Readiness Level (TRL) |
| 9 |
User Feedback Sources |
| Indifferent/No user feedback |
Supporting Documentation |
| Docs: identiFINDER S900 Datasheet-LTR 21-1110_WEB (1).pdf; |
Dimensions |
| 25.8 x 2.5 in (654 x 63 mm) |
Weight |
| <10 Lbs.; 5.3 Lbs. (2.4 kg) |
Power Requirements |
| AC/DC Line Power; via ethernet |
Noise Produced |
| Negligible |
Transportability |
| Handheld |
Ruggedness |
| Extreme Temperatures/Humidity; Waterproof/Resistant; Dust; IP54 |
Operating Conditions |
| -20 to 50°C ( -4 to 122°F) |
Consumables |
| None |
Calibration Schedule |
| Automatic |
Suggested Routine Maintenance |
| Recommended 2 year service interval |
Available Accessories |
| Mounts, Belt cassette, wall adapter |
Data Analysis Support Equipment |
| Windows® CE operating system |
Communications Interface |
| Ethernet RJ45, 10 Mbit/s, 100 Mbit/s |
Expected Operational Life |
| Indefinite |
Shelf Life |
| >5 years |
Radiological Targets |
| Gamma, Neutron |
Adaptability |
| No; cannot detect or add new targets |
Sample Introduction |
| Radioactive Particle |
Sensitivity/Detection Limits |
| µSv; GM range 100 µSv/h – 10 mSv/h (10 mrem/h – 1.0 rem/h). Scintillator range 0 µSv/h – 100 Sv/h (0 rem/h – 10 mrem/h). |
Start Up Time (From Cold Start To Sample Ready) |
| 15 min |
Response Time (Sample Application To Output) |
| Continuous (<30 seconds) |
Total Run Time |
| Continuous |
Software Control |
| PC |
Other Operational Parameters |
| Energy range 20 keV to 3 MeV. Dose rate range 0.01 µµSv/h to 1 Sv/h (1.0 µrem/h – 100 rem/h). NaI detector. |
Training Required |
| <1 day training |
Training Available |
| Yes |
Manuals Available |
| Yes |
Warranties |
| Yes |
ITAR/EAR Export Regulations |
| Yes; These products are controlled for export under US Department of Commerce (DOC), Export Administration Regulations (EAR). U.S. Government authorization may be required. |