7250 GC/Q-TOF
The Agilent 7250 GC/Q-TOF uses high-resolution for mass screening by GC/MS and compound identification through MS/MS, low-energy electron ionization, and complimentary chemical ionization techniques.
Availability: Commercially Available
+1 816 427 5510
5301 Stevens Creek Boulevard
Santa Clara, CA 95051
USA
|
|
www.agilent.com
Manufacturer |
| Agilent Technologies |
Product Name |
| 7250 GC/Q-TOF |
Detection Category |
| Chemical; Explosives |
Detection Principle |
| Spectrometry; Chromatography; |
Detection Method |
| Gas Chromatography; Quadrupole Mass Spectrometry; |
Application |
| Laboratory Analysis; |
Equipment Type |
| Instrument |
Product Synopsis |
| The Agilent 7250 GC/Q-TOF uses high-resolution for mass screening by GC/MS and compound identification through MS/MS, low-energy electron ionization, and complimentary chemical ionization techniques. |
Availability |
| Commercially Available |
Technology Readiness Level (TRL) |
| 9 |
User Feedback Sources |
| Indifferent/No user feedback |
Dimensions |
| 34.6 x 39.4 x 74.8 in. (88 x 100 x 190 cm) |
Weight |
| >50 Lbs. |
Power Requirements |
| AC/DC Line Power |
Noise Produced |
| None |
Transportability |
| Benchtop/Fixed |
Ruggedness |
| Indoor Use Only |
Consumables |
| >$1,000/year |
Solvents/Reagents |
| Helium carrier gas, solvents for standards |
Calibration Schedule |
| Calibration required for each target chemical to determine GC retention time and detector response. |
Suggested Routine Maintenance |
| Source cleaning, filter cartridge replacement, pump oil change |
Data Analysis Support Equipment |
| ChemStation or Mass Hunter Software |
Communications Interface |
| USB, Ethernet, RS232 |
Expected Operational Life |
| >10 years |
Shelf Life |
| >5 years; Product lifetime indefinite with routine maintenance. Serviceability for ten years |
Tested For Chemical Agents |
| Amenable based on technology |
Tested For ITF-25 TIC/TIMs |
| Amenable based on technology |
Tested For Explosives |
| Amenable based on technology |
Tested For Narcotics |
| Amenable based on technology |
Other Chemical Targets |
| Applicable to all organic compounds amenable to GC |
Number of Library Entries |
| NIST |
Adaptability |
| Yes; user can add new targets in the field |
Sample Introduction |
| Liquid; Vapor/gas |
Sensitivity/Detection Limits |
| %; ng; µg |
False Positive Rates |
| <1% |
False Negative Rates |
| <1% |
Start Up Time (From Cold Start To Sample Ready) |
| 1 to 2 hours for internal heaters to reach operating temperatures |
Response Time (Sample Application To Output) |
| >15 minutes; 2 to 30 minutes typical response time, depending on analyte and GC method |
Software Control |
| On-board; PC |
Other Operational Parameters |
| mass range m/z 20 to 1050 |
Training Required |
| >1 week training |
Training Available |
| On-site and off-site training available from vendor |
Manuals Available |
| Operator’s Manual |
Warranties |
| 1 year factory warranty. 3 year extended warranty and service contract are available at additional cost. Up to 5 year service contracts are also available. |
IATA Shipping Restrictions |
| Yes; Compressed gas cylinders must be shipped ground only according to IATA regulations. |
Data File Type Format |
| XML, PDF |