CL17sc Colorimetric Chlorine Analyzer
The CL17sc is a colorimetric Chlorine Analyzer. It can continuously monitor water for free or total chlorine unattended for 30 days. Also suitable for permanganate residual measurements.
Availability: Commercially Available
| Manufacturer |
| Hach |
| Product Name |
| CL17sc Colorimetric Chlorine Analyzer |
| Detection Category |
| Chemical |
| Detection Principle |
| Colorimetric; |
| Detection Method |
| Colorimetric; |
| Application |
| Screening; |
| Product Model Number |
| 8572700; 8572800; 8572900; 8573000; 8572300; 8572400 |
| Equipment Type |
| Instrument |
| Product Synopsis |
| The CL17sc is a colorimetric Chlorine Analyzer. It can continuously monitor water for free or total chlorine unattended for 30 days. Also suitable for permanganate residual measurements. |
| Availability |
| Commercially Available |
| Technology Readiness Level (TRL) |
| 9 |
| User Feedback Sources |
| Indifferent/No user feedback |
| Dimensions |
| 12.9 x 13.46 x 6.95 in ( 32.755 x 34.2 x 17.648 cm) |
| Weight |
| <30 Lbs.; 9.0 Lbs. (4.1 kg) |
| Power Requirements |
| 12 VDC, 400 mA maximum |
| Noise Produced |
| Negligible |
| Transportability |
| Mounted |
| Ruggedness |
| Dust; Waterproof/Resistant; IP66 |
| Operating Conditions |
| 5 to 40°C (41 to 104°F); 0-90% RH, non-condensing |
| Consumables |
| <$1,000/year; reagents; Tubing Kit; Cell Cleaning Kit |
| Solvents/Reagents |
| DPD Indicator; Free Chlorine Indicator Solution; Free Chlorine Buffer Solution |
| Suggested Routine Maintenance |
| None |
| Available Accessories |
| Calibration Verification Kit, Calibration Verification Refill Kit, Standpipe Installation Kit, Pressure Regulator Installation Kit; |
| Data Analysis Support Equipment |
| None |
| Expected Operational Life |
| Indefinite |
| Shelf Life |
| >5 years |
| Maintenance Cost |
| None |
| Tested For ITF-25 TIC/TIMs |
| Chlorine, permanganate |
| Adaptability |
| No; cannot detect or add new targets |
| Sample Introduction |
| Liquid |
| Sensitivity/Detection Limits |
| mg/L |
| Known Interferents/Inhibitors |
| Other oxidizing agents such as bromide, chlorine dioxide, permanganate, and ozone will cause a positive interference. Hardness must not exceed 1,000 mg/L CaCO3 |
| Response Time (Sample Application To Output) |
| <5 minutes; 2.5 minutes |
| Total Run Time |
| <5 minutes; 2.5 minutes |
| Software Control |
| On-board |
| Training Required |
| <1 day training |
| Training Available |
| Yes |
| Manuals Available |
| Yes |
| Warranties |
| Yes |