UV-3600i Plus
The UV-3600i Plus UV-Vis_NIR spectrophotometer is capable of measuring in the UV, Visible, and up to 3,300 nm in NIR. It is equipped with double grating monochromators to minimize stray light levels. Optical resolution of 0.1nm in the UV and Vis regions and 0.4 nm in NIR region. Wavelength range is 182 nm to 3,300 nm.
Availability: Commercially Available
Greg Feldman
Sr. Field Sales Engineer
gsfeldman@shimadzu.com
1-913-888-9449, Ext. 1270
8052 Reeder Street
Lenexa, KS 66214
Midwest Regional Office
|
Jason Kuchar, Ph. D.
Life Science account Manager
jakuchar@shimadzu.com
1-913-888-9449, Ext. 1265
8052 Reeder Street
Lenexa, KS 66214
Midwest Regional Office
|
www.ssi.shimadzu.com
Manufacturer |
| Shimadzu |
Product Name |
| UV-3600i Plus |
Detection Category |
| Chemical; Explosives |
Detection Principle |
| Molecular Spectroscopy; |
Detection Method |
| Ultraviolet-Visible; Near Infrared; |
Application |
| Laboratory Analysis; |
Equipment Type |
| Instrument |
Product Synopsis |
| The UV-3600i Plus UV-Vis_NIR spectrophotometer is capable of measuring in the UV, Visible, and up to 3,300 nm in NIR. It is equipped with double grating monochromators to minimize stray light levels. Optical resolution of 0.1nm in the UV and Vis regions and 0.4 nm in NIR region. Wavelength range is 182 nm to 3,300 nm. |
Availability |
| Commercially Available |
Technology Readiness Level (TRL) |
| 9 |
User Feedback Sources |
| Indifferent/No user feedback |
Weight |
| >50 Lbs. |
Power Requirements |
| AC/DC Line Power |
Noise Produced |
| None |
Transportability |
| Benchtop/Fixed |
Ruggedness |
| Indoor Use Only |
Operating Conditions |
| Indoor Use Only |
Consumables |
| <$1,000/year |
Solvents/Reagents |
| None |
Available Accessories |
| ISR-1503 integrating sphere attachment, ASR-3105/3112/3130/3145 absolute reflectance attachment, variable angle measurement unit fo MPC-603A, Large polarizer set Type I, Type II, type III |
Data Analysis Support Equipment |
| Software, PC |
Expected Operational Life |
| Indefinite |
Shelf Life |
| >5 years |
Tested For Chemical Agents |
| Amenable based on Technology |
Tested For ITF-25 TIC/TIMs |
| Amenable based on Technology |
Tested For Explosives |
| Amenable based on Technology |
Tested For Narcotics |
| Amenable based on Technology |
Other Chemical Targets |
| Amenable based on Technology |
Tested For Biological Agents |
| No |
Other Biological Targets |
| No |
Radiological Targets |
| No |
Sample Introduction |
| Liquid; Solid; Vapor/Gas |
Sensitivity/Detection Limits |
| Bulk; g; mg |
Response Time (Sample Application To Output) |
| <5 minutes |
Alarm Capability |
| None |
Software Control |
| PC |
Other Operational Parameters |
| Wavelength range is 182nm to 3,300 nm |
Training Required |
| <1 week training |
Training Available |
| Yes |
Manuals Available |
| Yes |
Warranties |
| Yes |