TGA 8000

The TGA 8000 can control the furnace temperature range from subambient to 1,200 °C. The system delivers heating rates from 0.1 °C to 500 °C/minute, and its low mass and forced-air cooling allow it to cool quickly for fast sample turnaround. For sample gas environment, the system provides two integral mass-flow controllers for balance and sample purge. Built-in gas switching from Pyris™ software makes switching easy, while optional gas mixing allows the blending of up to three reaction gases, with delivery direct to the sample area.

Notify me on updates of this product 

Availability: Commercially available

Jeffrey Foster
Sales Engineer
jeffrey.foster@perkinelmer.com
www.perkinelmer.com
Manufacturer
Perkin Elmer
Product Name
TGA 8000
Detection Category
Chemical; Explosives
Detection Principle
Thermal Analysis;
Detection Method
Thermo Gravimetric Analysis;
Application
Bulk Analysis; Laboratory Analysis;
Equipment Type
Instrument
Product Synopsis
The TGA 8000 can control the furnace temperature range from subambient to 1,200 °C. The system delivers heating rates from 0.1 °C to 500 °C/minute, and its low mass and forced-air cooling allow it to cool quickly for fast sample turnaround. For sample gas environment, the system provides two integral mass-flow controllers for balance and sample purge. Built-in gas switching from Pyris™ software makes switching easy, while optional gas mixing allows the blending of up to three reaction gases, with delivery direct to the sample area.
Availability
Commercially available
Technology Readiness Level (TRL)
9
User Feedback Sources
Indifferent/No user feedback
Weight
>50 Lbs.
Power Requirements
AC/DC Line Power
Noise Produced
Negligible
Transportability
Benchtop/Fixed
Ruggedness
Indoor use only
Operating Conditions
Indoor use only
Consumables
<$1,000/year
Solvents/Reagents
None
Data Analysis Support Equipment
Data analysis software
Expected Operational Life
Indefinite
Shelf Life
>5 years
Tested For Chemical Agents
Amenable by Technology
Tested For ITF-25 TIC/TIMs
Amenable by Technology
Tested For Explosives
Amenable by Technology
Tested For Narcotics
Amenable by Technology
Other Chemical Targets
Amenable by Technology
Adaptability
No; cannot detect or add new targets
Sample Introduction
Liquid; Solid
Sensitivity/Detection Limits
Bulk; mg; g; %
Response Time (Sample Application To Output)
<15 minutes
Software Control
PC
Training Required
>1 week training
Training Available
Yes
Manuals Available
Yes
Reachback Service
Yes
Warranties
5 year parts only furnace warranty
Please enter contact info.
Email Address: 
Company: 
Name: 
Title: