X-Pulse
X-Pulse is a high-resolution benchtop NMR
spectrometer. Using a high stability 60MHz (1.4T)
permanent magnet X-Pulse enables users to
collect NMR data without the need for liquid
cryogens or specialist facilities. X-Pulse has been
optimized with unique shimming technology to
provide resolution of better than 0.35Hz. For
convenience, X-Pulse uses standard 5mm NMR
tubes requiring only 300µL of sample.
X-Pulse is the first benchtop NMR system to
have a broadband X-Nuclei channel allowing
users to select nuclei from 29Si to 31P.
Availability: Commercially Available
| Manufacturer |
| Oxford Instruments |
| Product Name |
| X-Pulse |
| Detection Category |
| Chemical |
| Detection Principle |
| Molecular Spectroscopy; |
| Detection Method |
| Nuclear Magnetic Resonance ; |
| Application |
| Laboratory Analysis; |
| Equipment Type |
| Instrument |
| Product Synopsis |
| X-Pulse is a high-resolution benchtop NMR
spectrometer. Using a high stability 60MHz (1.4T)
permanent magnet X-Pulse enables users to
collect NMR data without the need for liquid
cryogens or specialist facilities. X-Pulse has been
optimized with unique shimming technology to
provide resolution of better than 0.35Hz. For
convenience, X-Pulse uses standard 5mm NMR
tubes requiring only 300µL of sample.
X-Pulse is the first benchtop NMR system to
have a broadband X-Nuclei channel allowing
users to select nuclei from 29Si to 31P. |
| Availability |
| Commercially Available |
| Technology Readiness Level (TRL) |
| 9 |
| User Feedback Sources |
| Indifferent/No user feedback |
| Dimensions |
| 15.2 x 21.3 x 16.7in (38.5 x 54.0 x 42.5 cm) |
| Weight |
| >50 Lbs.; 330 Lbs. (150 kg) |
| Power Requirements |
| AC/DC Line Power; 100-240V |
| Noise Produced |
| Neglibible |
| Transportability |
| Benchtop/Fixed |
| Ruggedness |
| Indoor use only |
| Operating Conditions |
| Ambient temperatures |
| Consumables |
| <$1,000/year; solvents, NMR tubes (5mm) |
| Solvents/Reagents |
| Deuterated solvents |
| Expected Operational Life |
| Indefinite |
| Shelf Life |
| >5 years |
| Tested For Chemical Agents |
| Chemical agents that have protons or fluorine (1H, 19F) can be detected with same system configuration |
| Tested For ITF-25 TIC/TIMs |
| TIC/TIM that have protons or fluorine (1H, 19F) can be detected with same system configuration |
| Tested For Explosives |
| Explosives (nitro aromatics, organic peroxides) that have protons (1H) can be detected |
| Other Chemical Targets |
| Chemicals that have protons or fluorine (1H, 19F) can be detected with same system configuration |
| Sample Introduction |
| Liquid; Solid |
| Sensitivity/Detection Limits |
| mg; % |
| Start Up Time (From Cold Start To Sample Ready) |
| < 1 hour |
| Response Time (Sample Application To Output) |
| >15 minutes; 10 sec – hours |
| Alarm Capability |
| No |
| Software Control |
| PC |
| Training Required |
| <1 week training |
| Training Available |
| Yes |
| Manuals Available |
| Operator’s Manual |