X-Pulse
X-Pulse is a high-resolution benchtop NMR
spectrometer. Using a high stability 60MHz (1.4T)
permanent magnet X-Pulse enables users to
collect NMR data without the need for liquid
cryogens or specialist facilities. X-Pulse has been
optimized with unique shimming technology to
provide resolution of better than 0.35Hz. For
convenience, X-Pulse uses standard 5mm NMR
tubes requiring only 300µL of sample.
X-Pulse is the first benchtop NMR system to
have a broadband X-Nuclei channel allowing
users to select nuclei from 29Si to 31P.
Availability: Commercially Available
Manufacturer |
| Oxford Instruments |
Product Name |
| X-Pulse |
Detection Category |
| Chemical |
Detection Principle |
| Molecular Spectroscopy; |
Detection Method |
| Nuclear Magnetic Resonance ; |
Application |
| Laboratory Analysis; |
Equipment Type |
| Instrument |
Product Synopsis |
| X-Pulse is a high-resolution benchtop NMR
spectrometer. Using a high stability 60MHz (1.4T)
permanent magnet X-Pulse enables users to
collect NMR data without the need for liquid
cryogens or specialist facilities. X-Pulse has been
optimized with unique shimming technology to
provide resolution of better than 0.35Hz. For
convenience, X-Pulse uses standard 5mm NMR
tubes requiring only 300µL of sample.
X-Pulse is the first benchtop NMR system to
have a broadband X-Nuclei channel allowing
users to select nuclei from 29Si to 31P. |
Availability |
| Commercially Available |
Technology Readiness Level (TRL) |
| 9 |
User Feedback Sources |
| Indifferent/No user feedback |
Dimensions |
| 15.2 x 21.3 x 16.7in (38.5 x 54.0 x 42.5 cm) |
Weight |
| >50 Lbs.; 330 Lbs. (150 kg) |
Power Requirements |
| AC/DC Line Power; 100-240V |
Noise Produced |
| Neglibible |
Transportability |
| Benchtop/Fixed |
Ruggedness |
| Indoor use only |
Operating Conditions |
| Ambient temperatures |
Consumables |
| <$1,000/year; solvents, NMR tubes (5mm) |
Solvents/Reagents |
| Deuterated solvents |
Expected Operational Life |
| Indefinite |
Shelf Life |
| >5 years |
Tested For Chemical Agents |
| Chemical agents that have protons or fluorine (1H, 19F) can be detected with same system configuration |
Tested For ITF-25 TIC/TIMs |
| TIC/TIM that have protons or fluorine (1H, 19F) can be detected with same system configuration |
Tested For Explosives |
| Explosives (nitro aromatics, organic peroxides) that have protons (1H) can be detected |
Other Chemical Targets |
| Chemicals that have protons or fluorine (1H, 19F) can be detected with same system configuration |
Sample Introduction |
| Liquid; Solid |
Sensitivity/Detection Limits |
| mg; % |
Start Up Time (From Cold Start To Sample Ready) |
| < 1 hour |
Response Time (Sample Application To Output) |
| >15 minutes; 10 sec – hours |
Alarm Capability |
| No |
Software Control |
| PC |
Training Required |
| <1 week training |
Training Available |
| Yes |
Manuals Available |
| Operator’s Manual |