amaZon SL
The amaZon SL ion trap instrument is designed to increase productivity in the analytical lab for any application, such as for quality control, structural confirmation and screening of complex mixtures. Integrates with a wide variety of LC-systems, sample preparation modules and API sources, giving access to multiple ionization methods.
Availability: Commercially Available
Manufacturer |
| Bruker Corporation |
Product Name |
| amaZon SL |
Detection Category |
| Chemical; Explosives |
Detection Principle |
| Spectrometry; Chromatography |
Detection Method |
| Ion Trap Mass Spectrometry; Liquid Chromatography |
Application |
| Laboratory Analysis; |
Equipment Type |
| Instrument |
Product Synopsis |
| The amaZon SL ion trap instrument is designed to increase productivity in the analytical lab for any application, such as for quality control, structural confirmation and screening of complex mixtures. Integrates with a wide variety of LC-systems, sample preparation modules and API sources, giving access to multiple ionization methods. |
Availability |
| Commercially Available |
Technology Readiness Level (TRL) |
| 9 |
User Feedback Sources |
| Indifferent/No user feedback |
Weight |
| >50 Lbs. |
Power Requirements |
| AC/DC Line Power |
Noise Produced |
| Negligible |
Transportability |
| Benchtop/Fixed |
Ruggedness |
| Indoor Use Only |
Operating Conditions |
| Indoor Use Only |
Consumables |
| >$1,000/year |
Solvents/Reagents |
| Mobile phase reagents; solvents for standards |
Calibration Schedule |
| Calibration required for each target chemical to determine LC retention time and detector response. |
Expected Operational Life |
| Indefinite |
Shelf Life |
| >5 years |
Tested For Chemical Agents |
| Amenable based on technology |
Tested For ITF-25 TIC/TIMs |
| Amenable based on technology |
Tested For Explosives |
| Amenable based on technology |
Tested For Narcotics |
| Amenable based on technology |
Adaptability |
| Yes; user can add new targets in the field |
Sample Introduction |
| Liquid |
Sensitivity/Detection Limits |
| ppm; ng; µg |
Start Up Time (From Cold Start To Sample Ready) |
| <1 hour |
Response Time (Sample Application To Output) |
| >15 minutes |
Alarm Capability |
| None |
Software Control |
| PC |
Other Operational Parameters |
| Dual Ion Funnel technology; Scanning speeds up to 32,000 u/s; Fragmentation is possible up to the MS11 stage |
Training Required |
| <1 week training |
Training Available |
| In-person, videos |
Manuals Available |
| Operator's manual |
Reachback Service |
| Yes |
Warranties |
| Yes |