amaZon SL

The amaZon SL ion trap instrument is designed to increase productivity in the analytical lab for any application, such as for quality control, structural confirmation and screening of complex mixtures. Integrates with a wide variety of LC-systems, sample preparation modules and API sources, giving access to multiple ionization methods.

Notify me on updates of this product 

Availability: Commercially Available

Frank Thibodeau
Vice President of Business Development
frank.thibodeau@brukerdetection.us
+1 978 663 3660
40 Manning Road
Billerica, MA 01821
USA
www.bruker.com
Manufacturer
Bruker Corporation
Product Name
amaZon SL
Detection Category
Chemical; Explosives
Detection Principle
Spectrometry; Chromatography
Detection Method
Ion Trap Mass Spectrometry; Liquid Chromatography
Application
Laboratory Analysis;
Equipment Type
Instrument
Product Synopsis
The amaZon SL ion trap instrument is designed to increase productivity in the analytical lab for any application, such as for quality control, structural confirmation and screening of complex mixtures. Integrates with a wide variety of LC-systems, sample preparation modules and API sources, giving access to multiple ionization methods.
Availability
Commercially Available
Technology Readiness Level (TRL)
9
User Feedback Sources
Indifferent/No user feedback
Weight
>50 Lbs.
Power Requirements
AC/DC Line Power
Noise Produced
Negligible
Transportability
Benchtop/Fixed
Ruggedness
Indoor Use Only
Operating Conditions
Indoor Use Only
Consumables
>$1,000/year
Solvents/Reagents
Mobile phase reagents; solvents for standards
Calibration Schedule
Calibration required for each target chemical to determine LC retention time and detector response.
Expected Operational Life
Indefinite
Shelf Life
>5 years
Tested For Chemical Agents
Amenable based on technology
Tested For ITF-25 TIC/TIMs
Amenable based on technology
Tested For Explosives
Amenable based on technology
Tested For Narcotics
Amenable based on technology
Adaptability
Yes; user can add new targets in the field
Sample Introduction
Liquid
Sensitivity/Detection Limits
ppm; ng; µg
Start Up Time (From Cold Start To Sample Ready)
<1 hour
Response Time (Sample Application To Output)
>15 minutes
Alarm Capability
None
Software Control
PC
Other Operational Parameters
Dual Ion Funnel technology; Scanning speeds up to 32,000 u/s; Fragmentation is possible up to the MS11 stage
Training Required
<1 week training
Training Available
In-person, videos
Manuals Available
Operator's manual
Reachback Service
Yes
Warranties
Yes