MPA-II

MPA-II is a near-IR spectrometer designed for quality assurance and method development. The system is equipped with an internal sample compartment for transmission measurements. The MPA II can be upgraded by additional sampling accessories, like fiber optic probes, integrating sphere, external transmission unit, automated sample wheel, and sample rotators.

Notify me on updates of this product 

Availability: Commercially Available

Frank Thibodeau
Vice President of Business Development
frank.thibodeau@brukerdetection.us
+1 978 663 3660
40 Manning Road
Billerica, MA 01821
USA
www.bruker.com
Manufacturer
Bruker Corporation
Product Name
MPA-II
Detection Category
Chemical; Explosives
Detection Principle
Molecular Spectroscopy;
Detection Method
Near Infrared ;
Application
Laboratory Analysis; Bulk Analysis;
Equipment Type
Instrument
Product Synopsis
MPA-II is a near-IR spectrometer designed for quality assurance and method development. The system is equipped with an internal sample compartment for transmission measurements. The MPA II can be upgraded by additional sampling accessories, like fiber optic probes, integrating sphere, external transmission unit, automated sample wheel, and sample rotators.
Availability
Commercially Available
Technology Readiness Level (TRL)
9
User Feedback Sources
Indifferent/No user feedback
Dimensions
14.6 x 23.6 x 10.3in (37.1 x 60 x 26.2cm)
Weight
>50 Lbs.; 82 Lbs. (37kg)
Power Requirements
AC/DC Line Power
Noise Produced
Negligible
Transportability
Benchtop/Fixed
Ruggedness
Indoor use only
Operating Conditions
5 to 35° (41 to 95°F)
Consumables
<$1,000/year
Solvents/Reagents
None
Data Analysis Support Equipment
OPUS software
Communications Interface
Ethernet
Expected Operational Life
Indefinite
Shelf Life
>5 years
Tested For Chemical Agents
Amenable based on technology
Tested For ITF-25 TIC/TIMs
Amenable based on technology
Tested For Explosives
Amenable based on technology
Tested For Narcotics
Amenable based on technology
Number of Library Entries
Multiple libraries available
Adaptability
Yes; user can add new targets in the field
Sample Introduction
Solid; Liquid
Sensitivity/Detection Limits
ppm; Bulk; mg
Known Interferents/Inhibitors
Fluorescence
Response Time (Sample Application To Output)
<5 minutes
Alarm Capability
None
Software Control
PC
Other Operational Parameters
Resolution 2 cm-1; Tungsten air cooled source; Solid state laser; spectral range 11,500 - 4,000 cm-1; Class 1 laser.
Training Required
<1 week training
Training Available
In-person, videos
Manuals Available
Operator's manual
Reachback Service
Yes
Warranties
Yes