TargetScreener HR

The TargetSreener is a UHR QTOF mass spectrometer with Full Scan MS and broadband CID (bbCID) MS/MS methods. It is designed for both targeted and non-targeted workflows in routine and research laboratory environments. TargetScreener performs simultaneous detection and quantitation of multiple targets in a large variety of different matrices.

Notify me on updates of this product 

Availability: Commercially Available

Frank Thibodeau
Vice President of Business Development
frank.thibodeau@brukerdetection.us
+1 978 663 3660
40 Manning Road
Billerica, MA 01821
USA
www.bruker.com
Manufacturer
Bruker Corporation
Product Name
TargetScreener HR
Detection Category
Chemical; Explosives
Detection Principle
Spectrometry; Chromatography;
Detection Method
Time-of-Flight Mass Spectrometry; Liquid Chromatography;
Application
Laboratory Analysis;
Equipment Type
Instrument
Product Synopsis
The TargetSreener is a UHR QTOF mass spectrometer with Full Scan MS and broadband CID (bbCID) MS/MS methods. It is designed for both targeted and non-targeted workflows in routine and research laboratory environments. TargetScreener performs simultaneous detection and quantitation of multiple targets in a large variety of different matrices.
Availability
Commercially Available
Technology Readiness Level (TRL)
9
User Feedback Sources
Indifferent/No user feedback
Weight
>50 Lbs.
Power Requirements
AC/DC Line Power
Noise Produced
Negligible
Transportability
Benchtop/Fixed
Ruggedness
Indoor Use Only
Operating Conditions
Indoor Use Only
Consumables
>$1,000/year; columns
Solvents/Reagents
Mobile phase reagents; solvents for standards
Calibration Schedule
Calibration required for each target chemical to determine LC retention time and detector response.
Data Analysis Support Equipment
TASQ software
Expected Operational Life
Indefinite
Shelf Life
>5 years
Tested For Chemical Agents
Amenable based on technology
Tested For ITF-25 TIC/TIMs
Amenable based on technology
Tested For Explosives
Amenable based on technology
Tested For Narcotics
Amenable based on technology
Number of Library Entries
>3000
Adaptability
Yes; user can add new targets in the field
Sample Introduction
Liquid
Sensitivity/Detection Limits
ppm; ng; µg
Start Up Time (From Cold Start To Sample Ready)
<1 hour
Response Time (Sample Application To Output)
>15 minutes
Alarm Capability
None
Software Control
PC
Other Operational Parameters
Up to 10 annotated qualifier ions per target
Training Required
<1 week training
Training Available
In-person, videos
Manuals Available
Operator's manual
Reachback Service
Yes
Warranties
Yes
Please enter contact info.
Email Address: 
Company: 
Name: 
Title: