LIQUISCAN

LIQUISCAN is a liquid explosives, narcotics and Toxic Industrial Chemicals (TIC’s) detector capable of liquid vapor detection. Its patented HF-QCM nanotechnology sensors provide the latest threat detection and identification capabilities applicable to H202, Nitroglycerine, Nitromethane and many others. The unit uses direct vapor sniffing via a vapor nozzle.

Notify me on updates of this product 

Availability: Commercially Available

+1 703 465 5101
1655 Fort North Myer Drive Suite 700
Arlington, VA 22209
www.ms-technologies.com
Manufacturer
MS Technologies Inc.
Product Name
LIQUISCAN
Detection Category
Chemical; Explosives;
Detection Principle
Sensors;
Detection Method
High Frequency Quartz Crystal Microbalance;
Application
Bulk Analysis;Emergency Response;Screening;
Equipment Type
Instrument;
Product Synopsis
LIQUISCAN is a liquid explosives, narcotics and Toxic Industrial Chemicals (TIC’s) detector capable of liquid vapor detection. Its patented HF-QCM nanotechnology sensors provide the latest threat detection and identification capabilities applicable to H202, Nitroglycerine, Nitromethane and many others. The unit uses direct vapor sniffing via a vapor nozzle.
Availability
Commercially Available
Technology Readiness Level (TRL)
9
User Feedback Sources
Indifferent/No user feedback
Dimensions
19.87 x 13.93 x 4.68 in (221 x 71 x 86 cm)
Weight
<5 Lbs.; 1.5 Lbs. (0.66 kg) with battery
Power Requirements
Lithium Battery;
Transportability
Handheld
Ruggedness
Extreme Temperatures/Humidity
Operating Conditions
-20 to 55°C (-4 to 131°F)
Consumables
None
Calibration Schedule
Self-calibration
Available Accessories
USB printer
Communications Interface
Mini USB Port, Bluetooth, Wi-Fi,
Expected Operational Life
Indefinite
Shelf Life
>5 years
Tested For ITF-25 TIC/TIMs
Hydrazine, Acetone, Acetonitrile, Ethanol, Ammonia, and others. Additional TIC’s upon expandable threat library
Tested For Explosives
Hydrogen Peroxide, Nitromethane, Hydrazine, Astrolite, Nitroglycerine, EGDN and Water Gel. Additional explosives upon expandable threat library.
Adaptability
No; cannot detect or add new targets
Sample Introduction
Vapor/Gas;
Sensitivity/Detection Limits
ng; ppm
False Positive Rates
<2%
Start Up Time (From Cold Start To Sample Ready)
2 minutes
Response Time (Sample Application To Output)
Continuous (<30 seconds)
Alarm Capability
Audible and visual
Software Control
On-board
Other Operational Parameters
High-Frequency Quartz Crystal Microbalance Sensors (HF-QCM). No gas carrier. No radioactive source.
Training Required
<1 day training
Training Available
Yes
Manuals Available
User manual