RadEye GF10 Simulator
The RadEye GF 10 SIM responds to Radsim electromagnetic sources that safely simulate ionizing radiation. The simulator is built tactically and can be used in and outdoors.
Availability: Commercially Available
Manufacturer |
| Argon Electronics |
Product Name |
| RadEye GF10 Simulator |
Detection Category |
| Radiological/Nuclear; |
Detection Principle |
| Simulation Training; |
Detection Method |
| Electromagnetic; |
Application |
| Simulation Training; |
Product Model Number |
| F414NXX-N004 |
Equipment Type |
| Accessory; |
Product Synopsis |
| The RadEye GF 10 SIM responds to Radsim electromagnetic sources that safely simulate ionizing radiation. The simulator is built tactically and can be used in and outdoors. |
Availability |
| Commercially Available |
Technology Readiness Level (TRL) |
| 9 |
Market Entry Date |
| N/A |
User Feedback Sources |
| Indifferent/No user feedback |
Dimensions |
| 1.2" x 2.4" x 3.8" |
Weight |
| <1 Lbs |
Power Requirements |
| Same commercial or rechargable batteries as real detector. |
Noise Produced |
| Same as Manufacturer |
Transportability |
| Handheld; |
Ruggedness |
| Same as Manufacturer |
Operating Conditions |
| Same as Manufacturer |
Consumables |
| Commercial Batteries Only |
Calibration Schedule |
| N/A |
Suggested Routine Maintenance |
| Requires no preventative maintenance and spares are minimized to reduce the cost of ownership. |
Available Accessories |
| N/A |
Data Analysis Support Equipment |
| N/A |
Communications Interface |
| N/A |
Expected Operational Life |
| Indefinite |
Shelf Life |
| >5 years |
Maintenance Cost |
| None |
Sample Introduction |
| Simulated Radiation Activity Detection |
Start Up Time (From Cold Start To Sample Ready) |
| <2 minutes |
Response Time (Sample Application To Output) |
| Continuous (<30 seconds); < 10 seconds |
Total Run Time |
| Continuous |
Alarm Capability |
| Visual/Audible |
Software Control |
| Onboard |
Other Operational Parameters |
| Inverse square law (1/r2) response within real detector tolerance.
Simulation of user body shielding for source location.
Realistic representation of different shielding effects.
Selectable units of measurement (Sv/hr, Rem, CPS).
Same human interface as real RadEye.
Configurable menu settings.
Dose and dose rate alarm settings.
Language selection.
Same commercial batteries as real detector (80 hours operation).
PlumeSIM compatible. |
Training Required |
| <1 day training |
Training Available |
| Yes |
Manuals Available |
| Yes |
Reachback Service |
| N/A |
Warranties |
| 1 YR - Return to Manufactuer |
ITAR/EAR Export Regulations |
| NO |
U.S. EAR Compliant |
| Yes |
IATA Shipping Restrictions |
| NO |
Approved Vendors |
| Contact Argon Electronics |
Data File Type Format |
| N/A |