AP4C+

The AP4C+ is a easy-to-use wearable, handeld, and projectable chemical threat detector. The AP4C+ is a connected chemical threat detector that can measure and detect chemical threats in the air in real time. Whether you need to protect your special forces while on mission, confirm/deny presence of a chemical threat on a scene ,or analyse presence of a CWA agent in the unknown, the AP4C+ alerts you thanks to its extremely fast response time, sensitivity, and ability to be projected on UAV or UGV 3rd party solutions.

Notify me on updates of this product 

Availability: Commercially Available

Scott Hartley
CEO
scott.hartley@proengin.com
+1 954 760 9990
1321 Central Park Boulevard, Suite 408
Fredericksburg, VA 22402
USA
www.proengin.com
Manufacturer
Proengin, Inc.
Product Name
AP4C+
Detection Category
Chemical;
Detection Principle
Elemental Analysis;
Detection Method
Flame Spectroscopy;
Application
Emergency Response; Gas Analysis;
Equipment Type
Instrument
Product Synopsis
The AP4C+ is a easy-to-use wearable, handeld, and projectable chemical threat detector. The AP4C+ is a connected chemical threat detector that can measure and detect chemical threats in the air in real time. Whether you need to protect your special forces while on mission, confirm/deny presence of a chemical threat on a scene ,or analyse presence of a CWA agent in the unknown, the AP4C+ alerts you thanks to its extremely fast response time, sensitivity, and ability to be projected on UAV or UGV 3rd party solutions.
Availability
Commercially Available
Technology Readiness Level (TRL)
9
Market Entry Date
2023
User Feedback Sources
Indifferent/No user feedback
Supporting Documentation
Docs: AP4C Plus Data Sheet.pdf;
Dimensions
8,3 x 7,1 x 2,5 in (210 x 180 x 64 mm)
Weight
<5 lbs.; 2.86 lbs (1.3 kg)
Power Requirements
Lithium Battery; Rechargeable
Noise Produced
Low humming sound
Transportability
Handheld
Ruggedness
Extreme Temperatures/Humidity; IP63; Dust; Vibration/Shock; MIL-STD-810H, MIL-STD-461F
Operating Conditions
-32°C to +50°C (-25°F to +122°F) Operational altitude: 10,000 feet Humidity 3 to 100% HR (non-condensing)
Consumables
<$1,000/year; refilling or replace for the Hydrogen cylinder (4 hours autonomy); Lithium ion batteries
Calibration Schedule
Self-test on startup requires no user input
Suggested Routine Maintenance
4 hours with Mini Hydrogen cylinder Recommended preventive maintenance of 1 year
Available Accessories
S4PE: sampling solution for liquid and solid measurement S4PF: enhanced sampling solution for liquid and solid measurement External audio solution External vibration solution Hard sleeve
Data Analysis Support Equipment
Computer
Communications Interface
RS422
Expected Operational Life
10 years
Shelf Life
>5 years
Maintenance Cost
No maintenance until 1,000 hours of operation or every 1 years. No maintenance required for 10 years if in storage.
Tested For Chemical Agents
Any chemical that contains target elements will produce a response (P, HNO bond, As and/or S). All nerve, blister, and blood agents: GA, GB, GD, GF, VX, HD, HN-1, HN-2, HN-3, CX, L, HL, PD, ED, MD, AC, CK, SA, DA, DM, DC, BZ, CNS, CA, CS, CR, PS, Runcol, Precursor of OPA, Precursor of DF, EDMP
Tested For ITF-25 TIC/TIMs
Any chemical that contains target elements will produce a response (P, HNO bond, As and/or S). Carbon disulfide, hydrogen sulfide, sulfur dioxide, sulfuric acid, phosphorus trichloride, arsine, ammonia, HCN, carbonyl sulfide, chlorosulfonic acid, methanesulfonyl chloride, phosphorus oxychloride, PF5, sulfur trioxide, sulfuryl chloride, sulfuryl fluoride, arsenic trichloride, dimethyl sulfate, ethyl phosphonothioic dichloride, ethyl phosphoric dichloride, and tetraethyl pyrophosphate.
Other Chemical Targets
Any chemical that contains target elements will produce a response (P, HNO bond, As and/or S).
Adaptability
Not applicable; Elemental analysis performs on any threats containing P, S, As, HNO, within LOD limits; Elemental analysis do not use librairy
Sample Introduction
Liquid; Vapor/Gas; Solid
Sensitivity/Detection Limits
µg; ppb
Known Interferents/Inhibitors
Any chemical that contains target elements will produce a response (P, HNO bond, As and/or S).
Start Up Time (From Cold Start To Sample Ready)
1 min for temperatures between 0 and 20°C (32°F to 68°F)
Response Time (Sample Application To Output)
Continuous (vapor, gas, aerosols) from 1 to 16 sec Discontinuous with S4PE/ S4PF (solids, liquids) 30 sec to 1 min
Alarm Capability
Audible and Visual (Internal)
Software Control
On-board with an accessory, PC, wired or wireless with an accessory, UGV and UAV integration
Other Operational Parameters
Yes
Training Required
<1 day training
Training Available
Manufacturer training
Manuals Available
Operator’s Manual
Warranties
1 year; extended warranties are available
ITAR/EAR Export Regulations
No; dual use item
IATA Shipping Restrictions
Yes; IATA restrictions apply to hydrogen cartridges and Lithium ion batteries.