DMC 3000

The DMC 3000 Electronic Dosimeter has a unique, high contrast and backlit LCD display that provides a clear indication of wearer’s dose and ambient dose rate for deep dose equivalent. More importantly, multiple methods (audible, visual, and tactile) are utilized to alert the wearer of alarm conditions. The DMC 3000 provides protection, for over 3,000 hours of continuous use, with a single AAA alkaline battery. The DMC 3000 offers detection and radio transmission capabilities.

Notify me on updates of this product 

Availability: Commercially Available

Carol McGowan
Homeland Security and Defense Sales Manager
cmcgowan@mirion.com
+1 770 329 3228
5000 Highlands Parkway Suite 150
Smyrna, GA 30082
USA
www.mirion.com
Manufacturer
Mirion Technologies
Product Name
DMC 3000
Detection Category
Radiological/Nuclear;
Detection Principle
Geiger-Muller Detectors;
Application
Personal Radiation Detectors;
Product Model Number
DMC 3000
Equipment Type
Instrument;
Product Synopsis
The DMC 3000 Electronic Dosimeter has a unique, high contrast and backlit LCD display that provides a clear indication of wearer’s dose and ambient dose rate for deep dose equivalent. More importantly, multiple methods (audible, visual, and tactile) are utilized to alert the wearer of alarm conditions. The DMC 3000 provides protection, for over 3,000 hours of continuous use, with a single AAA alkaline battery. The DMC 3000 offers detection and radio transmission capabilities.
Availability
Commercially Available
Technology Readiness Level (TRL)
9
User Feedback Sources
None
Supporting Documentation
Docs: dmc-3000-spec-sheet-spc-84-en-b.pdf;
Dimensions
87 x 60 x 21 mm (3.4 x 2.3 x 0.8 in)
Weight
< 88 g (3.1 oz) with alkaline battery
Power Requirements
standard AAA (LR03) 1.5 V Alkaline, 3000hr battery life
Transportability
Pocket Size;
Ruggedness
Shock, vibration and drop resistant (1.5 meter on concrete) Waterproof IP67: 1m (39 in) during 1 hour
Operating Conditions
-10°C to 50°C (14°F to 122°F)
Consumables
Battery
Communications Interface
Bluetooth option
Radiological Targets
Gamma, x-ray radiation
Sample Introduction
Radioactive Particle
Sensitivity/Detection Limits
0.001 mrem to 10000 rem
Response Time (Sample Application To Output)
Dose increments with a 1 µSv (0.1 mrem) resolution and dose rate saved on non-volatile memory (EEPROM) in configurable steps (10 s, 60 s, 10 min, 1 hour, 24 hours)
Alarm Capability
Visual, audible, vibration
Manuals Available
Yes
Approved Vendors
Laurus Systems, Inc.
Please enter contact info.
Email Address: 
Company: 
Name: 
Title: