D5 RIID
The D5 RIID is a small, light, 3.5% resolution, wearable Radioisotope Identification Device (RIID) with an expansive radioisotope library and a low false alarm rate. It continuously scans and accurately identifies radiological threats in real time, even in mixed source environments.
Availability: Commercially Available
Manufacturer |
| Kromek Group plc |
Product Name |
| D5 RIID |
Detection Category |
| Radiological/Nuclear; |
Detection Principle |
| Scintillation Detectors; |
Application |
| Personal Radiation Detectors; |
Product Model Number |
| D5 RIID |
Equipment Type |
| Instrument; |
Product Synopsis |
| The D5 RIID is a small, light, 3.5% resolution, wearable Radioisotope Identification Device (RIID) with an expansive radioisotope library and a low false alarm rate. It continuously scans and accurately identifies radiological threats in real time, even in mixed source environments.
|
Availability |
| Commercially Available |
Technology Readiness Level (TRL) |
| 9 |
User Feedback Sources |
| None |
Supporting Documentation |
| Docs: D5 RIID A4E SPF-DOC-1269 rev6.pdf; |
Dimensions |
| 187 x 80 x 70mm |
Weight |
| 660 g (1.47 lb) |
Power Requirements |
| 3 x AA, or rechargeable (>24hrs) |
Transportability |
| Handheld; |
Ruggedness |
| Designed to meet MIL-STD-810G |
Operating Conditions |
| -20ºC to 50ºC |
Consumables |
| Batteries |
Data Analysis Support Equipment |
| software and PC |
Communications Interface |
| Bluetooth, WIFI, USB |
Radiological Targets |
| Gamma and neutron |
Sample Introduction |
| Radioactive Particle |
Sensitivity/Detection Limits |
| 30 keV to 3 MeV |
Response Time (Sample Application To Output) |
| 30 seconds to 5 minutes for identification |
Alarm Capability |
| Visual, audible, vibration |