D3S ID
A wearable, concealable Gamma and Neutron detector which puts the power of a RIID into a package the size of a Personal Radiation Detector (PRD).
D3S ID has extended detection capabilities that enable safe monitoring in potentially high dose environments. The D3S ID has a simple user interface, with both visual and audio status updates and notifications. It records all detection information and can send the data through Reachback to a central command center where quick and informed decisions can be made.
The detection algorithm provides substantial enhancements in the detection and identification of low activity shielded threats, masked threats and nuisance isotopes and has been extensively tested and characterized in multiple CWMD and DARPA programs.
Availability: Commercially Available
Manufacturer |
| Kromek Group plc |
Product Name |
| D3S ID |
Detection Category |
| Radiological/Nuclear; |
Detection Principle |
| Scintillation Detectors; |
Detection Method |
| Scintillation Detectors; |
Application |
| Personal Radiation Detectors; |
Product Model Number |
| D3S ID |
Equipment Type |
| Instrument; |
Product Synopsis |
| A wearable, concealable Gamma and Neutron detector which puts the power of a RIID into a package the size of a Personal Radiation Detector (PRD).
D3S ID has extended detection capabilities that enable safe monitoring in potentially high dose environments. The D3S ID has a simple user interface, with both visual and audio status updates and notifications. It records all detection information and can send the data through Reachback to a central command center where quick and informed decisions can be made.
The detection algorithm provides substantial enhancements in the detection and identification of low activity shielded threats, masked threats and nuisance isotopes and has been extensively tested and characterized in multiple CWMD and DARPA programs. |
Availability |
| Commercially Available |
Technology Readiness Level (TRL) |
| 9 |
User Feedback Sources |
| Indifferent/No user feedback |
Supporting Documentation |
| Docs: D3S ID (NS) Brochure.pdf; |
Dimensions |
| 5.2" x 3.1" x 0.9" (132 mm x 80 mm x 23.5 mm) |
Weight |
| <1 lb.; 0.52 lbs (237 g) |
Power Requirements |
| Lithium Battery; 1100mAh Lithium polymer (12 hours); 1450 mAh Lithium polymer |
Noise Produced |
| none |
Transportability |
| Pocket Size; |
Ruggedness |
| -20°C to 50°C, meets ANSI N42.32 section 7.1, section 7.2, section 7.5; Up to 93% RH ANSI N42.32 section 7.3; IP53 as per ANSI N42.32 section 7.4 |
Operating Conditions |
| -20 to 50°C (-4 to 122°F) |
Calibration Schedule |
| SiPM array LED auto-calibration |
Available Accessories |
| Charging via USB or inductive charging |
Data Analysis Support Equipment |
| Cell phone, PC |
Communications Interface |
| Mini-USB, bluetooth |
Expected Operational Life |
| Indefinite |
Radiological Targets |
| Gamma, neutron |
Number of Library Entries |
| 42 isotopes – 22 more than ANSI N42.34 standard
Discriminates between Medical, NORM, Industrial and SNM classes
69 unique signatures which accounts for shielding and mixed configurations |
Adaptability |
| Yes; user can add new targets to detector with support |
Sample Introduction |
| Particle; |
Sensitivity/Detection Limits |
| CPS: 5 cps/µR/h (500 cps/µSv/h) Photo peak 1.2 cps/µR/h (120 cps/µSv/h) |
False Positive Rates |
| 1 in 24 hours |
Start Up Time (From Cold Start To Sample Ready) |
| Seconds to minutes |
Response Time (Sample Application To Output) |
| Continuous (<30 seconds) |
Total Run Time |
| Continuous |
Alarm Capability |
| Audible, visual, vibration |
Software Control |
| Remote |
Other Operational Parameters |
| Energy range: 30 keV to 3.0 MeV |
Training Required |
| <1 day training |
Manuals Available |
| User's Manual |
Warranties |
| 1 year |
IATA Shipping Restrictions |
| Yes; Lithium ion battery |
Data File Type Format |
| SPE, CSV |