AFS Aerosol Fluorescence Sensor

The Aerosol Fluorescence Sensor (AFS) uses separate measurements on different parts of the fluorescence spectrum to differentiate biological particles from fluorescing man-made pollutant particles in the atmosphere. Fluorescence detection output 1 is 300 - 420 nm (UV); fluorescence detection output 2 is 420 - 650 nm (visible). The AFS can be operated alone or in tandem with Biral’s Aspect particle size and shape analysis system to provide multi-parameter characterization.

Notify me on updates of this product 

Availability: DISCONTINUED

Paul Smith
P_Smith@Biral.Com
+44 (0)1275 847787
P.O. Box 2, Portishead,
Bristol, BS20 7JB, UK
www.biral.com
Manufacturer
Biral
Product Name
AFS Aerosol Fluorescence Sensor
Detection Category
Biological
Detection Principle
Molecular Spectroscopy;
Detection Method
Fluorescence;
Application
Emergency Response; Detection;
Equipment Type
Instrument
Product Synopsis
The Aerosol Fluorescence Sensor (AFS) uses separate measurements on different parts of the fluorescence spectrum to differentiate biological particles from fluorescing man-made pollutant particles in the atmosphere. Fluorescence detection output 1 is 300 - 420 nm (UV); fluorescence detection output 2 is 420 - 650 nm (visible). The AFS can be operated alone or in tandem with Biral’s Aspect particle size and shape analysis system to provide multi-parameter characterization.
Availability
DISCONTINUED
Technology Readiness Level (TRL)
9
User Feedback Sources
Indifferent/No user feedback
Dimensions
10.4 x 11.4 x 11 in (265 x 290 x 280 mm)
Weight
<30 lbs.; 11.3 lbs (5.3 kg)
Power Requirements
AC/DC Line Power; 90-260 VAC; 47-63 Hz
Transportability
Person-Portable
Operating Conditions
5 to 30 °C; 0 to 95% RH
Data Analysis Support Equipment
Air pump required for standalone operation (7 LPM)
Communications Interface
USB 1.0 or USB 2.0
Unit Cost
$25,132.00
Maintenance Cost
$20,435 as accessory to Aspect (at current exchange rate, British pound to US dollar)
Tested For Biological Agents
Biological particles
Sample Introduction
Vapor/Gas; Aerosol
Start Up Time (From Cold Start To Sample Ready)
Negligible
Response Time (Sample Application To Output)
Continuous (<30 seconds)
Other Operational Parameters
UV-Light Induced Fluorescence
Training Required
<1 day training
ITAR/EAR Export Regulations
Yes; If used in connection with any WMD activity, including research into detection systems, an export license will be required.