AFS Aerosol Fluorescence Sensor
The Aerosol Fluorescence Sensor (AFS) uses separate measurements on different parts of the fluorescence spectrum to differentiate biological particles from fluorescing man-made pollutant particles in the atmosphere. Fluorescence detection output 1 is 300 - 420 nm (UV); fluorescence detection output 2 is 420 - 650 nm (visible). The AFS can be operated alone or in tandem with Biral’s Aspect particle size and shape analysis system to provide multi-parameter characterization.
Availability: DISCONTINUED
| Manufacturer |
| Biral |
| Product Name |
| AFS Aerosol Fluorescence Sensor |
| Detection Category |
| Biological |
| Detection Principle |
| Molecular Spectroscopy; |
| Detection Method |
| Fluorescence; |
| Application |
| Emergency Response; Detection; |
| Equipment Type |
| Instrument |
| Product Synopsis |
| The Aerosol Fluorescence Sensor (AFS) uses separate measurements on different parts of the fluorescence spectrum to differentiate biological particles from fluorescing man-made pollutant particles in the atmosphere. Fluorescence detection output 1 is 300 - 420 nm (UV); fluorescence detection output 2 is 420 - 650 nm (visible). The AFS can be operated alone or in tandem with Biral’s Aspect particle size and shape analysis system to provide multi-parameter characterization. |
| Availability |
| DISCONTINUED |
| Technology Readiness Level (TRL) |
| 9 |
| User Feedback Sources |
| Indifferent/No user feedback |
| Dimensions |
| 10.4 x 11.4 x 11 in (265 x 290 x 280 mm) |
| Weight |
| <30 lbs.; 11.3 lbs (5.3 kg) |
| Power Requirements |
| AC/DC Line Power; 90-260 VAC; 47-63 Hz |
| Transportability |
| Person-Portable |
| Operating Conditions |
| 5 to 30 °C; 0 to 95% RH |
| Data Analysis Support Equipment |
| Air pump required for standalone operation (7 LPM) |
| Communications Interface |
| USB 1.0 or USB 2.0 |
| Unit Cost |
| $25,132.00 |
| Maintenance Cost |
| $20,435 as accessory to Aspect (at current exchange rate, British pound to US dollar) |
| Tested For Biological Agents |
| Biological particles |
| Sample Introduction |
| Vapor/Gas; Aerosol |
| Start Up Time (From Cold Start To Sample Ready) |
| Negligible |
| Response Time (Sample Application To Output) |
| Continuous (<30 seconds) |
| Other Operational Parameters |
| UV-Light Induced Fluorescence |
| Training Required |
| <1 day training |
| ITAR/EAR Export Regulations |
| Yes; If used in connection with any WMD activity, including research into detection systems, an export license will be required. |