Joint Biological Point Detection System (JBPDS)

Using laser-induced fluorescence, the JBPDS continuously evaluates the atmospheric background for traces of potential biological agents. When the system detects a potential threat, a collector/concentrator is triggered to collect hundreds of liters of air per minute with the particulates concentrated in a small amount of liquid. The liquid sample is then evaluated for specific biological agents using immunoassays. If the presence of biological agents is suspected, JBPDS triggers local and remote warning systems and communicates threat information over standard communication systems.

Notify me on updates of this product 

Availability: Commercially available

Wayne Horvath
Director of Sales
whorvath@chemringds.com
+1 980 235 2200
4205 Westinghouse Commons Drive
Charlotte, NC 28273
USA
www.chemringds.com
Manufacturer
Chemring Detection Systems
Product Name
Joint Biological Point Detection System (JBPDS)
Detection Category
Biological
Detection Principle
Molecular Spectroscopy;
Detection Method
Fluorescence;
Application
Laboratory Analysis; Detection;
Equipment Type
Instrument
Product Synopsis
Using laser-induced fluorescence, the JBPDS continuously evaluates the atmospheric background for traces of potential biological agents. When the system detects a potential threat, a collector/concentrator is triggered to collect hundreds of liters of air per minute with the particulates concentrated in a small amount of liquid. The liquid sample is then evaluated for specific biological agents using immunoassays. If the presence of biological agents is suspected, JBPDS triggers local and remote warning systems and communicates threat information over standard communication systems.
Availability
Commercially available
Technology Readiness Level (TRL)
9
User Feedback Sources
Indifferent/No user feedback
Dimensions
BBSU 30 x 36 x 20 in (76.2 x 91.4 x 50.8 cm), Power Pack 10 x 36 x 25 in (25.4 x 91.4 x 63.5 cm). ECU 30 in x 20 in x 13 in (76.2 x 50.8 x 33 cm).
Weight
>50 lbs.; BBSU 275 lbs (125 kg), Power Pack 200 lbs (91 kg). ECU 100 lbs (45.4 kg)
Power Requirements
AC/DC Line Power; 2,400 W max.
Transportability
Mounted
Ruggedness
Extreme Temperatures/Humidity; Waterproof/Resistant; Dust; Vibration/Shock; MIL_STD-810E
Operating Conditions
-28 to 50°C (-18 to 122°F)
Consumables
None
Solvents/Reagents
None
Data Analysis Support Equipment
None
Communications Interface
Standard communication systems
Expected Operational Life
Indefinite
Other Biological Targets
Bacteria, viruses, toxins
Sample Introduction
Vapor/Gas;Aerosol
Start Up Time (From Cold Start To Sample Ready)
Minutes
Response Time (Sample Application To Output)
Continuous (<30 seconds)
Total Run Time
Continuous monitor
Alarm Capability
Yes
Software Control
On-board
Training Required
<1 day training
Manuals Available
Yes
Please enter contact info.
Email Address: 
Company: 
Name: 
Title: