BTX-II

The BTX-II has the full XRD mineralogical analysis capabilities of the BTX Profiler, but only rudimentary XRF information gleaned from the CCD detector; it essentially aids in the XRD mineralogical identification and analysis as opposed to providing the full, rigorous elemental ED-XRF analysis found in the BTX Profiler. The BTX Profiler combines full XRD and full XRF capabilities. It uses single sample measurement or unattended multi-sample measurements with an integrated autosampler. Applications include: counterfeit drug screening, pharmaceutical discovery library building, and fire or explosives forensics.

Notify me on updates of this product 

Availability: Commercially Available

Kevin Coleman
Technical Sales Representative
kevin.coleman@olympus-ossa.com
+1 312 520 2974
48 Woerd Avenue
Waltham, MA 02453
USA
www.olympus-ims.com
Manufacturer
Olympus Scientific Solutions America
Product Name
BTX-II
Detection Category
Chemical; Explosives
Detection Principle
Elemental Analysis;
Detection Method
X-ray Diffraction (XRD); X-ray Fluorescence ;
Application
Laboratory Analysis; Bulk Analysis;
Equipment Type
Instrument
Product Synopsis
The BTX-II has the full XRD mineralogical analysis capabilities of the BTX Profiler, but only rudimentary XRF information gleaned from the CCD detector; it essentially aids in the XRD mineralogical identification and analysis as opposed to providing the full, rigorous elemental ED-XRF analysis found in the BTX Profiler. The BTX Profiler combines full XRD and full XRF capabilities. It uses single sample measurement or unattended multi-sample measurements with an integrated autosampler. Applications include: counterfeit drug screening, pharmaceutical discovery library building, and fire or explosives forensics.
Availability
Commercially Available
Technology Readiness Level (TRL)
9
Market Entry Date
2008
User Feedback Sources
Indifferent/No user feedback
Supporting Documentation
Docs: Olympus - BTX-II and BTX Profiler.pdf; MRIGlobal - BTXII.pdf;
Dimensions
BTX-II: Single sample unit 11.75 x 6.9 x 18.5 in (29.9 x 17.6 x 49.6 cm) BTX Profiler: Single sample unit -19.41 x 15.66 x 13.55 in (49.4 x 39.8 x 34.5 cm) Multi-Sample unit 26.57 x 15.66 x 13.55 (67.5 x 39.8 x 34.5 cm)
Weight
>50 Lbs.; BTX-II: 27.5 Lbs.(12.5 kg) BTX Profiler: 51 Lbs. (23.2 kg) BTX Profiler Multi-Sample: 72 Lbs. (32.7 kg)
Power Requirements
AC/DC Line Power; 110 to 220 VAC
Noise Produced
Negligible
Transportability
Benchtop/Fixed; Small Footprint
Ruggedness
Vibration/Shock
Operating Conditions
-10 to 35 °C (14 to 95 °F)
Consumables
<$1,000/year; Sample cells for the both XRD and for XRF, Mylar windows ($100/set of 10)
Suggested Routine Maintenance
Mylar window needs to be replaced approximately every 6 months. User can perform basic preventative maintenance; however, major repair work needs to be done by manufacturer.
Communications Interface
Ethernet or Wireless(802.11b/g)
Expected Operational Life
Indefinite
Shelf Life
>5 years
Unit Cost
$53,750.00
Maintenance Cost
$100
Tested For ITF-25 TIC/TIMs
Yes
Tested For Explosives
Yes
Tested For Narcotics
Yes
Other Chemical Targets
Elemental Analysis
Number of Library Entries
Commercial databases available
Adaptability
Yes
Sample Introduction
Solid
Sensitivity/Detection Limits
%; ppm; 100's ppm to %
Start Up Time (From Cold Start To Sample Ready)
2 minutes
Response Time (Sample Application To Output)
<15 minutes; 5 to 15 minutes
Total Run Time
5 to 15 minutes
Software Control
On-board
Other Operational Parameters
XRD range: 5 to 55°, 0.25° resolution, XRF Energy Range: 3 to 25 keV, 200 eV resolution, Sample Size: 15 mg; X-Ray tube voltage: 30kV, X-ray tube power: 10W, X-ray target material: Cu or Co (Cu standard), Sampling: Dry powder is placed into a small chamber.
Training Required
<1 day training
Training Available
Yes
Manuals Available
Operator’s Manual
Reachback Service
No
Warranties
1 year, extended warranty
ITAR/EAR Export Regulations
No
Data File Type Format
TXT
Please enter contact info.
Email Address: 
Company: 
Name: 
Title: