Single Advanced Gasmitter
The Single Advanced Gasmitter uses NDIR technology for the measurement of a wide array of gases for industrial applications.
Availability: Commercially Available
Manufacturer |
| Sensors, Inc. |
Product Name |
| Single Advanced Gasmitter |
Detection Category |
| Chemical |
Detection Principle |
| Molecular Spectroscopy; |
Detection Method |
| Non-Dispersive Infrared (NDIR); |
Application |
| Gas Analysis; |
Equipment Type |
| Sensor |
Product Synopsis |
| The Single Advanced Gasmitter uses NDIR technology for the measurement of a wide array of gases for industrial applications. |
Availability |
| Commercially Available |
Technology Readiness Level (TRL) |
| 9 |
User Feedback Sources |
| Indifferent/No user feedback |
Dimensions |
| 6.6 x 4.1 x 2.2 (168 x 103 x 56 mm) |
Weight |
| <5 lbs.; 1.8 lbs (800 g) |
Power Requirements |
| AC/DC Line Power; 24 VDC, Max 3W; 8W with heating option; 28W during warm up |
Transportability |
| Handheld |
Operating Conditions |
| 0 to 50°C (operating temperature) -20 to 60°C (storage temperature) 800 – 1200 mbar (gas pressure) <95% Relative Humidity, non-condensing 0.1 – 0.750 l/min (gas flow rate, constant) |
Calibration Schedule |
| Yes, Annually |
Communications Interface |
| RS-485 and USB |
Shelf Life |
| >5 years |
Unit Cost |
| $1,460.00 |
Maintenance Cost |
| Only recommended maintenance is annual recalibration |
Other Chemical Targets |
| CO, CO2, CH4, C6H14, C3H8, N2O |
Sample Introduction |
| Vapor/Gas |
Sensitivity/Detection Limits |
| ppm |
Known Interferents/Inhibitors |
| If measuring a hydrocarbon and different hydrocarbons are present this could present interference |
Start Up Time (From Cold Start To Sample Ready) |
| <30 minutes |
Response Time (Sample Application To Output) |
| <1 minute; 5-45 seconds |
Software Control |
| Software for programming/calibration |
Training Required |
| <1 day training |
Manuals Available |
| Yes |
Warranties |
| Yes 15 months |