Calomat 6 Continuous Gas Analyzer
The CALOMAT 6 is a high-end analyzer available in a 19" design or in a robust field unit for mounting in the open air. For continuous measurement of hydrogen and noble gases, the thermal conductivity of the sample gas mixture is measured and used to calculate the concentration. In general, its range of uses includes all areas from the measurement of gas purity measurement through process monitoring and controls to insure product quality. The CALOMAT 6 can carry out internal cross correction after transmission of the external measuring results. There is no need for an external computer.
Availability: Commercially Available
Manufacturer |
| Siemens Industry, Inc. |
Product Name |
| Calomat 6 Continuous Gas Analyzer |
Detection Category |
| Chemical |
Detection Principle |
| Sensors; |
Detection Method |
| Electrochemical Detection; Thermal Conductivity Detector (TCD); |
Application |
| Emergency Response; Gas Analysis; |
Equipment Type |
| Sensor |
Product Synopsis |
| The CALOMAT 6 is a high-end analyzer available in a 19" design or in a robust field unit for mounting in the open air. For continuous measurement of hydrogen and noble gases, the thermal conductivity of the sample gas mixture is measured and used to calculate the concentration. In general, its range of uses includes all areas from the measurement of gas purity measurement through process monitoring and controls to insure product quality. The CALOMAT 6 can carry out internal cross correction after transmission of the external measuring results. There is no need for an external computer. |
Availability |
| Commercially Available |
Technology Readiness Level (TRL) |
| 9 |
User Feedback Sources |
| Indifferent/No user feedback |
Dimensions |
| 17.2 x 18.9 x 12.2 in (438 x 480 x 311 mm) |
Weight |
| >50 lbs.; 55 lbs. (25 kg) |
Power Requirements |
| AC/DC Line Power; AC 100 V – 10% to 120 V + 10%, 47 to 63 Hz AC 200 V – 10% to 240 V + 10%, 47 to 63 Hz |
Transportability |
| Benchtop/Fixed |
Ruggedness |
| None; drop sensitive |
Operating Conditions |
| 5 to 45°C (operating temperature) -30 to 70°C (storage temperature) 0 to 50°C (gas inlet temperature) <90% Relative Humidity, must not fall below dew point <90% Relative Humidity, (gas inlet) 800 – 1100 hPa absolute (gas inlet pressure) |
Consumables |
| <$1,000/year; Carrier gas, calibration gas, sample gas, filters, fuses |
Calibration Schedule |
| Yes |
Available Accessories |
| Optional: AUTOCAL function with 8 additional binary inputs and relay outputs each, also with PROFIBUS PA or PROFIBUS DP |
Communications Interface |
| RS 485, Ethernet, PROFIBUS DP and PROFIBUS PA interfaces |
Unit Cost |
| $8,000.00 |
Other Chemical Targets |
| Primarily used for quantitative determination of H2 or He in binary or quasi-binary non-corrosive gas mixtures. Also measures: Ar, CO2, CH4, H2 in blast furnace gas 0 to 10% H2 in converter gas 0 to 20% H2 with wood gasification 0 and 30 % |
Sample Introduction |
| Vapor/Gas |
Sensitivity/Detection Limits |
| %; ppm |
Known Interferents/Inhibitors |
| Interfering gases: Ar, CH4, C2H6, C3H8, CO, CO2, H2O (non-linear response), NH3 (non-linear response), O2, SF6, SO2, Air (dry) |
Start Up Time (From Cold Start To Sample Ready) |
| < 30 minutes |
Response Time (Sample Application To Output) |
| Continuous (<30 seconds); <5 seconds |
Alarm Capability |
| Yes |
Software Control |
| May be parameterized and operated using a PDM tool. The analyzers can optionally communicate with the Siprom GA software tool that is integrated into the Ethernet via TCP/IP. |
Training Required |
| <1 week training |
Training Available |
| Yes |
Manuals Available |
| Operator’s Manual |
Warranties |
| 18 month |
IATA Shipping Restrictions |
| Yes; gases are regulated by IATA |