DE-tector

DE-tector is a drugs and explosives detection instrument with a non radioactive ionization source and a unique twin-tube design that measures for drugs and explosives at the same time. Surfaces such as luggage, laptops and cargo packages, can be wiped using special glass fiber coated sampling strips and a strip holder. Dedicated software algorithms and a reference library provide automatic detection of explosives at trace concentrations (low ng range) on many different surfaces. Target molecules collected on sampling strips are desorbed thermally at 250°C for 9 s. Afterwards the evaporated molecules are ionized using a low energy photoionization source (XPI™)

Notify me on updates of this product 

Availability: DISCONTINUED

Frank Thibodeau
Vice President of Business Development
frank.thibodeau@brukerdetection.us
+1 978 663 3661
41 Manning Road
Billerica, MA 01822
USA
www.bruker.com
Manufacturer
Bruker Corporation
Product Name
DE-tector
Detection Category
Chemical; Explosives
Detection Principle
Spectrometry;
Detection Method
Ion Mobility Spectrometry;
Application
Screening;Forensics;Bulk Analysis; Emergency Response;
Product Model Number
1824953
Equipment Type
Instrument
Product Synopsis
DE-tector is a drugs and explosives detection instrument with a non radioactive ionization source and a unique twin-tube design that measures for drugs and explosives at the same time. Surfaces such as luggage, laptops and cargo packages, can be wiped using special glass fiber coated sampling strips and a strip holder. Dedicated software algorithms and a reference library provide automatic detection of explosives at trace concentrations (low ng range) on many different surfaces. Target molecules collected on sampling strips are desorbed thermally at 250°C for 9 s. Afterwards the evaporated molecules are ionized using a low energy photoionization source (XPI™)
Availability
DISCONTINUED
Technology Readiness Level (TRL)
9
Market Entry Date
2016
User Feedback Sources
Indifferent/No user feedback
Supporting Documentation
Docs: Bruker - DEtector.pdf;
Dimensions
20 x 17 x 15 in (51 x 43.5 x 38 cm)
Weight
<50 Lbs.; 40 Lbs. (18 kg)
Power Requirements
AC/DC Line Power; 96V AC to 240V AC, 47 to 63 Hz
Noise Produced
Negligible
Transportability
Benchtop/Fixed; Small Footprint
Ruggedness
Waterproof/Resistant; IP20
Operating Conditions
0 to 45°C (32 to 113°F), < 95% RH, non-condensing
Consumables
<$1,000/year; Sampling strips, solution strips, drying filter, dopant, thermal paper, test marker (confidence sample
Suggested Routine Maintenance
User can perform basic maintenance, No preventive maintenance required
Available Accessories
Mobile cart, Telescopic extension sampling wand, dust cover
Data Analysis Support Equipment
Printer, software
Communications Interface
USB 3.0, LAN
Expected Operational Life
Indefinite
Shelf Life
>5 years
Unit Cost
$37,500.00
Maintenance Cost
<$1,000 per year in consumables
Tested For ITF-25 TIC/TIMs
Amenable based on technology
Tested For Explosives
Ammonium Nitrate (NIT), Urea Nitrate (NIT), Nitroglycerine (NG), Pentaerythritol tetranitrate (PETN), Trinitrotoluene (TNT), 2,4-Dinitrotoluene (DNT), Tetryl (TET), Hexogen (RDX), Octogen (HMX), Hexamethylene triperoxide diamine (HMTD), Triacetone triperoxide (TATP), 2,3-dimethyl-2,3-dinitrobutane (DMNB), Black powder (BP), Ethylene glycol dinitrate (EGDN)
Tested For Narcotics
Morphine (MORPH), 3,6-Diacetylmorphine (Heroin) (HER), Cocaine (COC), Cannabinol (CBD), ?9-Tetrahydrocannabinol (THC), 6-Acetylmorphine (6-AM), Amphetamine (AMPH), Methamphetamine (METH), 3,4-Methylenedioxyamphetamine (MDA), 3,4-Methylenedioxy-N-ethylamphetamine (MDEA), 3,4-Methylenedioxy-N-methylamphetamine (MDMA), Lysergic acid diethylamide (LSD), Phencyclidine (PCP), Ketamine (KET), Ephedrine (EPH), fentanyl, carfentanil, sufentanil, alfentanil, remifentanil, ketamine, lorazepam, 3-quinuclidinyl benzilate, U-47700
Other Chemical Targets
Yes, drug additives and others. Does not detect some cutting agents such as sugar.
Number of Library Entries
Explosives and Narcotics libraries
Adaptability
Yes; manufacturer can add new targets to detector
Sample Introduction
Liquid; Solid;
Sensitivity/Detection Limits
ng
Start Up Time (From Cold Start To Sample Ready)
< 30 minutes
Response Time (Sample Application To Output)
Continuous (<30 seconds); < 7 seconds
Total Run Time
1 minute
Alarm Capability
Visual
Software Control
On-board
Other Operational Parameters
Detector type: Twin tube IMS allowing for identification of both positive and negative ions simultaneously
Training Required
<1 day training
Training Available
Yes, 1-2 days at manufacturer
Manuals Available
Operator's Manual, administrator manual, maintenance manual, operator's manual DE-Control Center