NexION Series ICP-MS

The NexION ICP-MS systems are laboratory benchtop systems. The 1000 model is better for high-throughput, routine, multi-element, trace-level analyses. The 2000 model is versatile to accommodate any sample matrix, interference, and particle size. The 5000 model is a high resolution with four quadrupoles and includes an Extended Dynamic Range (EDR) that increases linear dynamic range to 10^12, allowing to run both high and low concentration analytes in a single analytical run.

Notify me on updates of this product 

Availability: Commercially available

Jeffrey Foster
Sales Engineer
jeffrey.foster@perkinelmer.com
www.perkinelmer.com
Manufacturer
Perkin Elmer
Product Name
NexION Series ICP-MS
Detection Category
Chemical
Detection Principle
Elemental Analysis;
Detection Method
Inductively Coupled Plasma Mass Spectrometry;
Application
Laboratory Analysis;
Product Model Number
NexION 5000, NexION 2000, NexION 1000
Equipment Type
Instrument
Product Synopsis
The NexION ICP-MS systems are laboratory benchtop systems. The 1000 model is better for high-throughput, routine, multi-element, trace-level analyses. The 2000 model is versatile to accommodate any sample matrix, interference, and particle size. The 5000 model is a high resolution with four quadrupoles and includes an Extended Dynamic Range (EDR) that increases linear dynamic range to 10^12, allowing to run both high and low concentration analytes in a single analytical run.
Availability
Commercially available
Technology Readiness Level (TRL)
9
User Feedback Sources
Indifferent/No user feedback
Weight
>50 Lbs.
Power Requirements
AC/DC Line Power
Noise Produced
Negligible
Transportability
Benchtop/Fixed
Ruggedness
Indoor use only
Operating Conditions
Indoor use only
Consumables
>$1,000/year
Solvents/Reagents
Mobile phase, solvent for standards
Suggested Routine Maintenance
RF coil requires no maintenance or cooling
Data Analysis Support Equipment
Syngistix™ for ICP-MS software (v. 3.0 or higher)
Expected Operational Life
Indefinite
Shelf Life
>5 years
Tested For Chemical Agents
Amenable by Technology
Tested For ITF-25 TIC/TIMs
Amenable by Technology
Tested For Explosives
Amenable by Technology
Tested For Narcotics
Amenable by Technology
Other Chemical Targets
Amenable by Technology
Adaptability
No; cannot detect or add new targets
Sample Introduction
Liquid
Sensitivity/Detection Limits
µg; %
Response Time (Sample Application To Output)
<15 minutes
Alarm Capability
None
Software Control
PC
Other Operational Parameters
Acquisition speed 100,000 points/sec
Training Required
>1 week training
Training Available
Yes
Manuals Available
Yes
Reachback Service
Yes
Warranties
1 year
Please enter contact info.
Email Address: 
Company: 
Name: 
Title: