B-SIM-P Probe
The RADSIM B-SIM-P is a Beta radiation safety training simulator probe for use with the Mirion / Canberra AN/PDR-77, RDS100 and CDV 718 survey meters.
Availability: Commercially Available
| Manufacturer |
| Argon Electronics |
| Product Name |
| B-SIM-P Probe |
| Detection Category |
| Radiological/Nuclear; |
| Detection Principle |
| Simulation Training; |
| Detection Method |
| Magnetic Point Contact Source; |
| Application |
| Simulation Training; |
| Product Model Number |
| F347FXX-L00Z |
| Equipment Type |
| Android Application |
| Product Synopsis |
| The RADSIM B-SIM-P is a Beta radiation safety training simulator probe for use with the Mirion / Canberra AN/PDR-77, RDS100 and CDV 718 survey meters. |
| Availability |
| Commercially Available |
| Technology Readiness Level (TRL) |
| 9 |
| Market Entry Date |
| N/A |
| User Feedback Sources |
| Indifferent/No user feedback |
| Dimensions |
| 10" x 2.75"x 3" |
| Weight |
| <1 Lbs |
| Power Requirements |
| Powered by radiac meter when connected |
| Noise Produced |
| Same as Manufacturer |
| Transportability |
| Handheld; |
| Ruggedness |
| Same as Manufacturer |
| Operating Conditions |
| Same as Manufacturer |
| Consumables |
| N/A |
| Calibration Schedule |
| N/A |
| Suggested Routine Maintenance |
| Requires no preventative maintenance and spares are minimized to reduce the cost of ownership. |
| Available Accessories |
| N/A |
| Data Analysis Support Equipment |
| N/A |
| Communications Interface |
| N/A |
| Expected Operational Life |
| Indefinite |
| Shelf Life |
| >5 years |
| Maintenance Cost |
| None |
| Sample Introduction |
| Simulated Radiation Activity Detection |
| Start Up Time (From Cold Start To Sample Ready) |
| <2 minutes |
| Response Time (Sample Application To Output) |
| Continuous (<30 seconds); < 10 seconds |
| Total Run Time |
| Continuous |
| Alarm Capability |
| Visual/Audible |
| Software Control |
| Onboard |
| Other Operational Parameters |
| For use with Canberra AN/PDR-77, RDS100 and CDV 718 radiac meter with the RDS-100BP probe
Simulation of Beta radiation response
Responds to safe Beta simulation sources that can be hidden on a person
Simulation of partial and full decontamination
No need to recalibrate your real instrument before or after use
Provided with an instructor remote control unit
PlumeSIM compatible. |
| Training Required |
| <1 day training |
| Training Available |
| Yes |
| Manuals Available |
| Yes |
| Reachback Service |
| N/A |
| Warranties |
| 1 YR - Return to Manufactuer |
| ITAR/EAR Export Regulations |
| NO |
| U.S. EAR Compliant |
| Yes |
| IATA Shipping Restrictions |
| NO |
| Approved Vendors |
| Contact Argon Electronics |
| Data File Type Format |
| N/A |